Operation when Using the Power Mist
In power mist operation, the airflow volume switches automatically as shown in the chart below
and after 30 minutes, turns to automatic operation. For operation following this, refer to the
section on automatic operation.
When the power mist is in operation, the power mist (green) lamp in the operating section on
top of the unit and the power mist (blue) lamp on the front of the unit will be lit. (The airflow
volume lamp will not be lit.)
At this time, the electrolyzed water lamp (green) in the operating section on top of the unit and
the electrolyzed water lamp (blue) on the front of the unit should both be lit, and when they are
off, there is an attachment error with the electrolyzing unit or the water tank.
The sterilized and electrolyzed mist is operated in power mode. (It cannot be selected when
electrolyzing is off.)
*The sterilized and electrolyzed mist is generated in a repeated 1 second on, 1 second off
intermittent operation.
Any timer period setting will be deleted when power mist operation is turned on, and it is also
not possible to set a timer period during power mist operation.
Even during power mist operation, the odor sensor and dust sensor operate individually, and
the clean sign is displayed depending on the operation of each sensor.
Power
Power
Power
Med
Med
High Med
Auto matic
High Med
High
High
Operation Time
Airflow Speed
Sterilized and
Electrolyzed Mist
Power ... 1 second on , 1second off - Intermittent operation of ultrasonic transducer
(5 minutes)
5 minutes
10 minutes
15 minutes
(10 minutes)
(15 minutes)
Front Electrolyzed Water Lamp
Upeer Electrolyzed Water Lamp
Upeer Power Mist Lamp
Front Power Mist Lamp
Operation of the Power Mist
ABC-VW24
- 10-