One hole is required for the air conditioner tubing, and
may be either on the left or right side. (Also see section
3-14. Preparing the Indoor Side Tubing.)
(1) Tape the full-scale installation diagram on the wall
at the location selected. Make sure the unit is
horizontal using a level or tape measure to
measure down from the ceiling. (Fig. 3-25)
(2) Determine if the hole is to be drilled at the left or
right hole location.
(3) Before drilling a hole, check that there are no
studs or pipes behind the determined location.
KH
3
072R, KH
3
672R
CAUTION
Avoid any area where electrical
wiring or conduit is located.
Also take this precaution if the
tubing goes through a wall at
any other location.
(4) Using a sabre saw, key hole saw or 3-5/32 in.
hole-cutting drill attachment, make a hole in the
wall. The required minimum hole diameter for
these models is 3-3/16 in. (Fig. 3-26)
(5) Measure the thickness of the wall from the inside
edge to the outside edge and cut PVC pipe at a
slight angle 1/4 in. shorter than the thickness of
the wall. (Fig. 3-27)
(6) Place the plastic cover over the end of the pipe,
(for indoor side only) and insert in the wall.
(Fig. 3-28)
Tape
F
u
ll-
s
cale
i
ns
tallatio
n
dia
g
ram
Fig.
3
-25
Indoor
side
Outdoor
side
Fig.
3
-26
Cut at slight angle
PVC pipe (locally purchased)
Fig.
3
-27
Plastic
cover
INSIDE
Wall
Slight
angle
PVC pipe
OUTSIDE
Fig.
3
-2
8
NOTE
Hole should be made at a slight downward slant to
the outdoor side.
05-354-1 PAC-i_II 2/13/06 6:37 PM Page 35