Maintenance Procedures
SY75C Excavator OMM
5-22
Operation and Maintenance Manual — 0220
SANY
Battery - Replacement
1. Remove two nuts and washers (b), then remove cover
(a).
2. Disconnect black ground (-) battery cables (c) first, then
disconnect red positive (+) cables (d) last.
3. Remove the nuts from the retaining bolts and lift
battery hold down bracket (e) off of the battery.
4. Remove the failed battery (or batteries).
5. Install the new battery (or batteries).
6. Connect red positive (+) cables first. Connect black
ground (-) cables.
NOTE:
Both 12 volt batteries are attached in series. Be
sure they are installed in the same manner.
NOTE:
Dispose of the old batteries properly.
7. Replace battery hold down (a) bracket over the battery and secure in place with nuts.
8. Reinstall cover (a) and two nuts and washers (b).
NOTICE!
Dispose of batteries in accordance with local
environmental regulations. Failure to do so
could result in damage to the environment.
Fig. 5-11
a
b
Fig. 5-12
e
c
d
_
+
Fig. 5-13
Summary of Contents for SY75
Page 2: ......