— 13 —
5-2 DC Voltage Measurement (
)
Function
Max. Rated Input
Range
DC 1000 V
110.00 mV, 1.1000 V, 11.000 V,
110.00 V, 1000.0 V
DCV measurement example
Remarks:
s
The DC 110 mV range can be selected with the
button.
Since this range is a high-input impedance, display may fluctuate or
show “OL” when the test leads are released. It is not a failure.