![Sanwa PC720M Instruction Manual Download Page 76](http://html.mh-extra.com/html/sanwa/pc720m/pc720m_instruction-manual_1198203076.webp)
― 73 ―
Frequency (Hz)
Measuring ranges
Input sensitivity*
Frequency ranges
60.00mV
40mV
15.00Hz to 50.00kHz
600.0mV
60mV
9.999V
2.5V
15.00Hz to 10.00kHz
99.99V
25V
999.9V
100V
600.0μA
60μA
15.00Hz to 3.000kHz
6000μA
600μA
60.00mA
40mA
600.0mA
60mA
6.000A
4A
10.00A
6A
Accuracy: ±0.04% rdg+ 4dgt
*Specified based on sine wave RMS
Logic level frequency (
) and Duty cycle (D%)
DCmV function
Range
Accuracy*
Frequency
5.000Hz to
1.000MHz
± (0.03%rdg+4 dgt)
Duty cycle
0.00% to
100.0%
± (3dgt/kHz+2 dgt) **
* Sensitivity: 2.5Vp (Square wave) for 3V and 5V logic family
** Specified Frequency: 5Hz to 10kHz
Summary of Contents for PC720M
Page 1: ...PC720M DIGITAL MULTIMETER INSTRUCTION MANUAL ...
Page 16: ... More than 1 second More than 1 second 13 ...
Page 21: ...0 5s 18 ...
Page 35: ... 32 ...
Page 36: ... 33 Note The display style of or does not show the bar graph ...
Page 39: ...m m 36 ...
Page 40: ...D 37 Note The display style of m m m m or D does not show the bar graph ...
Page 47: ...T1 T1 44 ...
Page 48: ...T2 T1 T2 45 ...
Page 51: ...Note Capacitance function does not show the bar graph 48 ...
Page 57: ...μ μ μ 54 ...
Page 58: ...μ μ μ Hz 55 ...
Page 79: ... 76 MEMO ...