![Sanwa PC710 Instruction Manual Download Page 31](http://html.mh-extra.com/html/sanwa/pc710/pc710_instruction-manual_1198168031.webp)
― 58 ―
― 57 ―
AC current (ACA), DC/AC current (DC/AC A)
Range
Accuracy
Input resistance**
DC, 50Hz
〜
60Hz
600.0
μ
A
±
(
0.6% rdg +3dgt
)
$SSUR[
6000
μ
A
60.00mA
$SSUR[
600.0mA
±
(
1.0% rdg +3dgt
)
6.000A
10.00A*
±
(
0.8% rdg +6dgt
)
$SSUR[
40Hz
〜
1kHz
600.0
μ
A
6000
μ
A
±
(
0.8% rdg +4dgt
)
$SSUR[
60.00mA
$SSUR[
600.0mA
±
(
1.0% rdg +4dgt
)
6.000A
10.00A*
±
(
0.8% rdg +6dgt
)
$SSUR[
* > 6A: Cool down more than 3 minutes after measuring 1 minute.
< 6A Continuable
**Fusing resistor not included
5HVLVWDQFH
Range
Accuracy
N
NN
0.1% rdg + 3dgt
0
0.4% rdg + 3dgt
0
1.5% rdg + 5dgt
99.99nS
0.8% rdg+10dgt
2SHQFLUFXLWYROWDJH9GF9GFIRU0UDQJH
Temp (
℃
&
o
F)**
Range
Accuracy*
-50
℃
〜
1000
℃
0.3% rdg + 2
℃
-58
o
F
〜
1832
o
F
0.3% rdg + 5
o
F
* Accuracy with K-type thermocouple K-type thermocouple range
and accuracy not included
**Cool down more than 30 minutes after measuring DCA or ACA.
Frequency (Hz)
Measuring ranges
Input sensitivity*
Frequency ranges
60.00mV
40mV
15.00Hz
〜
50.00kHz
600.0mV
60mV
9.999V
2.5V
15.00Hz
〜
10.00kHz
99.99V
25V
999.9V
100V
600.0
μ
A
60
μ
A
15.00Hz
〜
3.000kHz
6000
μ
A
600
μ
A
60.00mA
40mA
600.0mA
60mA
6.000A
4A
10.00A
7A
Accuracy: ±(0.04% rdg + 4dgt)
*Specified based on sine wave RMS
Logic level frequency (
) and Duty cycle (D%)
DCmV function
Range
Accuracy*
Frequency
5.000Hz
〜
1.000MHz
±
(
0.03%rdg+4dgt
)
Duty cycle
0.00%
〜
100.0%
±
(
3dgt/kHz+2dgt
)
**
* Input sensitivity: Square wave more than 2.5V
(3V and 5V logic family)
** Specified Frequency: 5Hz to 10kHz