DRAWING No. PC5000a 07-0812 2040 6010
[8] SPECIFICATIONS
8-1 General Specifications
Display:
4-4/5 digits 50000 counts LCD display (selectable 5-4/5 digits
500000 counts for DCV and 999999 counts for Hz)
Update Sampling Rate:
4-4/5 Digital data: 5 times / sec nominal
5-4/5 Digital data: 1.25 times / sec nominal
52 segments bar graph: 60 times / sec nominal
Low Battery Indication:
Below approx. 7V
Operating Temperature and Humidity:
0 to 30 , 0-80% RH; 31 to 50 , 0-50% RH No condensation
Storage Temperature/Humidity Range:
-20 to 60 , 80% RH MAX. No condensation
Altitude:
Operating below 2000m
Temperature Coefficient:
Nominal 0.15x(specified accuracy)/ @(0 -18 or 28 -50 ),
or otherwise specified
Power Supply:
Single alkaline 9V battery; NEDA1604A, IEC6LF22 or 6LR61
Sensing:
AC, AC+DC True RMS
Auto Power Off Timing:
Idle for 17 minutes
Safety:
IEC61010-1(EN61010-1) 2nd (2001)
V
/ /
Ω
• / /
Hz
: CAT for 600V DC & AC, and CAT for
1kV DC & AC
µA•mA
: CAT 500V AC & 300V DC
A
: CAT 500V AC & 300V DC
Transient Protection:
6.5kV (1.2/50µs surge)
D-1034-143
PC5000a(E)
— 35 —