IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.

Read and follow all instructions contained in 

this manual before using the product. Failure 

to comply with these instructions may result 

in personal injuries or damage to the unit or 

system.

1. 

Installation and servicing

 of air conditioning 

and related equipment 

can be hazardous

 due 

to systems pressure and electrical components. 

Only trained and qualified service personnel 

should install, repair or service equipment.

2. 

Untrained personnel

 can perform 

basic 

maintenance

 functions such as replacing 

lamp(s)  and/or  filter(s).  All  other  operations 

should be performed by trained service 

personnel.

3.  When working on the unit or system, observe 

precautions in the literature, tags and labels 

attached to the unit or system, and all other 

safety precautions considered as best practices 

in the HVAC industry.

4. When applicable, local regulation may 

comprise more restrictive installation and/or 

certification requirements. The afore mentioned 

requirements prevail on those of this document 

and the installer agrees to conform to these at 

his own expense.

5.  Follow all the safety instructions outlined in this 

document and respect all local and national 

codes applicable.

6. 

Never expose eyes or skin to ultraviolet light 

from any source.

 Therefore, 

before installing 

or performing maintenance

 on the unit or 

system, 

TURN OFF AND DISCONNECT

 the 

unit or system 

from all power sources

 (there 

may be more than one switch to disconnect).

 

 CAUTION:

 Electrical shock may cause 

personal injuries or possibly death.

7.  UV  rays  may  destroy  certain  types  of  filters 

(polymer or plastic); please keep the unit or 

system light away from shining directly on 

plastic.

8.  When installing or performing maintenance on 

the UV unit or system, it is recommended to 

wear safety glasses and gloves

. In order to 

avoid reduced performance of lamp(s), 

do not 

touch lamp glass without gloves

.

9.  UV lamps contain a small quantity of mercury: 

if a lamp breaks, clean and 

dispose of with 

care

. UV lamps can be disposed/recycled after 

use,  as  any  other  fluorescent  lamps.  Contact 

and  follow  your  local  and  national  authorities’ 

specific instructions.

10. Use  only  specified  SANUVOX  branded 

replacement UV lamps with your unit or 

system.

 Use of any other lamps will void your 

warranty and can result in damage to the unit, 

system and/or lamp(s).

11. Most UV units or systems are not waterproof. 

DO NOT INSTALL OUTDOORS

 unless 

specified otherwise.

SAVE THESE INSTRUCTIONS

Installation Date:  _______________   Installed by:  _________________
Installer Contact Info.:  _________________________________________

Summary of Contents for SR MAX

Page 1: ...xpense 5 Follow all the safety instructions outlined in this document and respect all local and national codes applicable 6 Never expose eyes or skin to ultraviolet light from any source Therefore before installing or performing maintenance on the unit or system TURN OFF AND DISCONNECT the unit or system from all power sources there may be more than one switch to disconnect CAUTION Electrical shoc...

Page 2: ...ction Activation 8 How to Reset your Product and its Lamp Timer 9 Step by Step Product and Lamp Timer Reset 9 MAINTENANCE 10 How to Replace Lamp s 10 Step by Step Lamp Replacement 10 How to Clean your Product 12 STORAGE 12 ULTRAVIOLETS UVV UVC 12 ELECTRICAL RATINGS POWER CONSUMPTION AVAILABLE VOLTAGE 12 TROUBLESHOOTING 12 What you will need 12 Internal Components 12 Problems Solutions Table 13 A S...

Page 3: ...allel to the UV J Lamp thus increasing contact time with the UV energy The Turbulator spins and mixes the air around the UV J Lamp First the UVV oxidizing section of the lamp boosted by Cobalt destroys chemicals and odors Then the UVC germicidal section of the lamp destroys the biological contaminants The Aluminum Reflector Chamber coated with cobalt amplifies the UV energy for optimal purificatio...

Page 4: ...ncludes a UV caution decal a maintenance decal a pair of cotton gloves metal screws for frame 6 Phillips screws for cover 4 and a frame Step by Step Setup Installation Check out Sanuvox Technologies YouTube Channel for the SR Max installation video 1 Prepare the SR Max for installation Remove the contents from packaging Only after you have visually inspected the UV lamp should you break the securi...

Page 5: ... 4 pins through the clamp Once the UV lamp is inserted release the clamp to fix the lamp in place 6 Once the UV lamp is installed reinstall the reflecting tube It is important to note that the air should first flow through the turbulator before moving in front of the UV lamp STEP 7 7 Prepare the duct return or supply for installation Evaluate the ideal area for installing the air purifier The refl...

Page 6: ...ing screws located in the 4 corners of the SR Max cover 8 Use the included metal frame to trace the outline onto the duct Allow for a 1 8 space around the marking as to allow the frame to sit properly in the duct The duct opening window should have the following dimensions 8 5 x 5 5 12 Use the power cord of the unit to plug into a wall outlet that provides the power as indicated on the marking lab...

Page 7: ... 20 C 60 to 70 F How to Read the LED Status Display The SR Max s LED Status Display will give you real time status update about your unit and its lamp Normal Operation GREEN In operation Default Mode ORANGE Heartbeat followed by 1 flash Lamp over 3 years that needs to be replaced BLUE Heartbeat Stand by waiting for airflow if Airflow Detection is activated At Start Up BLUE Airflow detection activa...

Page 8: ...ur unit is powered ON start by turning OFF the power switch 2 Use a small object similar to a paper clip and insert it into the reset hole in order to be able to press the reset button 3 First turn ON the power switch and then press the reset button You have 5 seconds from the moment the unit is powered to press the reset button to activate the airflow detection Every time you press the button you...

Page 9: ...imer Reset 1 To reset the lamp timer the unit needs to be powered and turned ON The status LED should either be Green or Blue heartbeat 2 Use a small object similar to a paper clip and insert it into the hole in order to be able to press the reset button 3 Press and hold the reset button for a minimum of 3 seconds When releasing the reset button the counter will be reset to 1096 days STEP 1 STEP 2...

Page 10: ...acement 1 Take the SR Max out from the ductwork by removing the 4 screws located on the cover 4 corners that hold it to the frame 2 Release the reflecting tube by removing the 2 screws on each side to access the lamp 4 Prepare the new lamp Remove the contents from packaging Only after you have visually inspected the UV lamp should you break the security seal on the underside of the cardboard sleev...

Page 11: ... that it can only be installed one way You may have to rotate the socket 90 to line up the pins with the holes The connector will fit into position NOTE Too much force applied from the opposite end cap may break the lamp 7 Slide the UV lamp porcelain end cap with 4 pins through the clamp Once the UV lamp is inserted release the clamp to fix the lamp in place 8 Once the UV lamp is installed reinsta...

Page 12: ...er expose eyes or skin to ultraviolet light from any source STORAGE The SR Max is an in duct unit working continuously and automatically and therefore requires no specific storage ELECTRICAL RATINGS POWER CONSUMPTION AVAILABLE VOLTAGE The product is rated at 120V to 240V and 50 Hz to 60 Hz See product label to confirm power consumption of your specific unit or system NOTE IF YOU EXPERIENCE A PROBL...

Page 13: ...s LED is RED with 3 flashes Thermistor is not connected Thermistor is damaged or defective Check thermistor connections Replace thermistor Status LED is RED with 4 flashes Thermistor is shorted Replace thermistor Status LED is BLUE with heartbeat Airflow detection activated waiting for airflow Turn the fan ON or set a higher speed to increase airflow circulating in the ductwork Reposition the SR M...

Page 14: ...old it to the frame 2 Place the SR Max on a flat surface and remove the 2 screws on each side that attach the cover to the ballast box 2 Release the reflecting tube by removing the 2 screws on each side to access the lamp Then remove the UV lamp from the lamp socket by opening the retaining clamp and pulling the UV lamp out of the reflector chamber 3 Using an ohmmeter place 1 probe on 1 of the 4 p...

Page 15: ...h the lamp and ballast are still functional 4 After the test is completed unplug the unit and replace the black wire from the cord in its original position identified Line STEP 2 STEP 3 STEP 4 D Step by Step Thermistor Deactivation 1 Open the SR Max ballast box see step by step instructions of the Ballast Box Opening on page 14 A STEP 2 2 Plug in the SR Max to a power source and turn ON the unit b...

Page 16: ...e B At its option SANUVOX will repair or replace this product if it is found to be defective in material or workmanship C This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual D This warranty does not cover the filters pre filters UV bulbs or other accessories if included except for material or workmansh...