STEP 3

Lamp installation

Open the access door and install the UV lamps on the connector using the supplied pair of gloves. When pushing the 

lamp into the connector, make sure your hand is holding the ceramic endcap and not the clear quartz part of the lamp and 

open the clamp at the same time. Once the lamp is firmly into position, release the clamp that will hold the lamp in place. 

Proceed the same with the two other lamps.

STEP 4

Operation

In consideration of the rooms air volume, turn ON, 1, 2 or 3 lamps.The “Maintenance” section below will give you a 

guidance on how many lamps could be turned ON with the air volume. Move the fan motor rheostat to the desired fan 

speed. The suggestion, if noise isn’t an issue, is to have the fan speed to its maximum position. Finally, close the door, 

power the unit by plugging it into a wall outlet of 120V.

Maintenance

Once a year change the UV lamps that are turned ON. 

Note

1

 : If one lamp out of 3 were turned ON, you can simply turn that lamp OFF and turn a second unused lamp ON. If 2 

lamps were turned ON, you can turn OFF the lamps that were ON, and turn ON the lamp that was OFF, and change the 

other two lamps and turn ON a second lamp, and so on.

Note

2

 : If only 1 or 2 lamps are turned ON, only the LED for those lamps will also be lit on the outside panel.

Parts for SANUVAIR

®

 S600

BST1201277GLR

Replacement ballast

LMPRGU65

Replacement lamp

Summary of Contents for SANUVAIR S600

Page 1: ...rved 2021 v 2 INSTALLATION MANUAL SANUVAIR S600 AIR PURIFICATION SYSTEM PLEASE SAVE FOR YOUR RECORDS DATE INSTALLED __________________________ INSTALLER CONTACT INFO ________________________________________________________________ INSTALLED BY ____________________________ ...

Page 2: ...ithout a pair of gloves The UV lamp contains a small amount of mercury dispose of the used lamp according to local regulations Use only Sanuvox branded replacement lamps The use of any other lamps will have a direct impact on the units performance and will void the warranty A Grill B Outlet fan motor C Aluminum chamber D UV lamp location E Inlet filter F Door contact G Fan speed control H Lamp ON ...

Page 3: ... over the unit for adequate air release A minimum clearance of 24 inches should be left under the unit for adequate air intake STEP 2 Mount system to wall After measuring the minimum clearance from the ceiling of the room mount and install the support bracket horizontally on the wall with the lip facing the ceiling 12in minimum clearance over the system 24in minimum clearance under the system Secu...

Page 4: ...ow will give you a guidance on how many lamps could be turned ON with the air volume Move the fan motor rheostat to the desired fan speed The suggestion if noise isn t an issue is to have the fan speed to its maximum position Finally close the door power the unit by plugging it into a wall outlet of 120V Maintenance Once a year change the UV lamps that are turned ON Note1 If one lamp out of 3 were...

Reviews: