1-888-726-8869 www.sanuvox.com
Sanuvox Technologies INC. All rights reserved. 2021-v.2
INSTALLATION MANUAL
STEP 3
Lamp installation
Open the access door and install the UV lamps on the connector using the supplied pair of gloves. When pushing the
lamp into the connector, make sure your hand is holding the ceramic endcap and not the clear quartz part of the lamp and
open the clamp at the same time. Once the lamp is firmly into position, release the clamp that will hold the lamp in place.
Proceed the same with the two other lamps.
STEP 4
Operation
In consideration of the rooms air volume, turn ON, 1, 2 or 3 lamps.The “Maintenance” section below will give you a
guidance on how many lamps could be turned ON with the air volume. Move the fan motor rheostat to the desired fan
speed. The suggestion, if noise isn’t an issue, is to have the fan speed to its maximum position. Finally, close the door,
power the unit by plugging it into a wall outlet of 120V.
Maintenance
Once a year change the UV lamps that are turned ON.
Note
1
: If one lamp out of 3 were turned ON, you can simply turn that lamp OFF and turn a second unused lamp ON. If 2
lamps were turned ON, you can turn OFF the lamps that were ON, and turn ON the lamp that was OFF, and change the
other two lamps and turn ON a second lamp, and so on.
Note
2
: If only 1 or 2 lamps are turned ON, only the LED for those lamps will also be lit on the outside panel.
Parts for SANUVAIR
®
S600
BST1201277GLR
Replacement ballast
LMPRGU65
Replacement lamp