INSTALLATION MANUAL
STEP 1
Pick ideal location
Locate a wall that the unit would be mounted on and where no cause for obstruction will prevent the units airflow to run
properly. The unit should be mounted vertically with the outlet fan position towards the ceiling and the inlet filter towards
the floor. A minimum clearance of 12 inches should be left over the unit for adequate air release. A minimum clearance of
24 inches should be left under the unit for adequate air intake.
STEP 2
Mount system to wall
After measuring the minimum clearance from the ceiling of the room, mount and install the support bracket horizontally on
the wall with the lip facing the ceiling.
12 in minimum clearance
over the system
24 in minimum clearance
under the system
Secure the bottom clamp on the wall where
a padlock can be installed to fasten the unit
at the bottom.
Using the units handles located on each
side of the system, position the unit on the
support bracket and center the unit from left
to right.