S300 VOC FOR SMOKING ROOM 

INSTALLER INSTRUCTIONS 

For a 2400 cubic feet maximum smoking room 

Please use these instructions along with the complete S300 instruction manual 

Box contains:  

 

One (1) S300 VOC unit that includes:

 

o

 

One (1) 

‘’J’’ lamp UVC/UVV with yellow tips (part 

LMPHGXJ105-1

     

2’’ expos

ed

o

 

One (1) 

‘’J’’ lamp all UVV with blue tips (part 

LMPHXJ105

o

 

Two (2) Multi voltage ballasts (part 

BST120/277GL

) and 2 lamp-holding brackets 

o

 

One (1) Relay (part 

MSCELC16

) connected to all UVV lamp  

o

 

Twenty (20) feet of wire that can be inserted in BX shield.  

o

 

One (1) VOC controller (part 

MSC1A

factory’s 

pre-set    

 

Two (2) replacement pre-filters (part 

MSCFTR10

)

                     

 

 LAMP INSTALLATION

 

 

1.

 

Remove the 6 screws on the front cover (The one with the SANUVOX logo). Put aside. 

2.

 

Remove the BLUE END CAP lamp from packaging. 

Use 

the gloves provided. 

3.

 

Insert the lamp in the second clamp and tighten. 
(furthest clamp from opening) 

4.

 

Holding the cap with one hand, plug the white 
connector tightly on the lamp 

5.

 

Remove the YELLOW END CAP lamp from packaging. 

Use the gloves provided.

 

6.

 

Insert the lamp in the first clamp and tighten. (closest 
to opening) 

7.

 

Holding the cap with one hand, plug the white 
connector tightly on the lamp 

8.

 

Put the cover back on with the 6 screws 

 

   Controller casing 

   Controller Opened 

              Relay   

 

20ft wiring 

Summary of Contents for S300 VOC

Page 1: ...ield o One 1 VOC controller part MSC1A factory s pre set Two 2 replacement pre filters part MSCFTR10 LAMP INSTALLATION 1 Remove the 6 screws on the front cover The one with the SANUVOX logo Put aside 2 Remove the BLUE END CAP lamp from packaging Use the gloves provided 3 Insert the lamp in the second clamp and tighten furthest clamp from opening 4 Holding the cap with one hand plug the white conne...

Page 2: ...u can replace it with BX cable with 3 wires WORKING INSTRUCTION The VOC controller analyzes the air every 90 seconds A 20 foot wire set connects it via a relay to activate the second oxidizing lamp on demand The S300 unit runs continuously so its regular lamp purifies the air constantly This dual zone lamp UVC UVV is enough when there are only one or two smokers However when the cigarette smoke in...

Page 3: ...REEN LED will turn solid Either blow cigarette smoke or propane gas into the controller the RED LED lights up and the relay will trigger on the oxidizing lamp all UVV This sequence reproduce itself every minute or so When there is no more smoke VOC the RED LED will turn off at the same time as the lamp Screw back the cover of the controller When the unit is powered the GREEN LED on the cover will ...

Page 4: ...ired concentration for the specific Volatile Organic Compound being sensed Note The value ofR8 can be changed to vary the range of the sensor A lower value decreases sensitivity increases range and a higher value increases sensitivity decreases range 6 2 red LEDs Led Lo D3 and Led Hi D2 are used to indicate the relay condition a Led Lo is ON when Relay Lo is ON and OFF when Relay Lo goes OFF b The...

Page 5: ...ects it via a relay to the device to activate the second oxidizing lamp on demand The S300 VOC unit runs continuously so its regular lamp purifies the air constantly This dual zone lamp UVC UVV is enough when there are only one or two smokers However if there is much smoke in the room the VOC controller that samples the air on a regular basis will then trigger the second all UVV lamp for a period ...

Reviews: