VOC CONTROLLER 

Remove the cover. 

Connect the 3 wires from the controller to the same color 
wiring coming from the unit. Use the wire connectors 
included.  

The detector is factory set a t 3.0 V DC; If you wish to set up a 
higher sensitivity, please proceed as follow. 

SETTING (if necessary) 

You will need a voltmeter with alligator probes. 

Place the probes one on the positive terminal, the other on the neutral terminal. 

Use a small screwdriver to turn the adjustment screw to increase the sensitivity of the controller. 
The default setting is 3.0 v dc. The more you increase the voltage, the faster the controller will react to 
VOC or smoke. 

 

CHECKING IF IT WORKS 

1.

 

Start the unit: inside the polycarbonate box, the GREEN LED flashes. It will take some time, so 
the electronic board initializes itself. 

2.

 

After 5 minutes, the GREEN LED will turn solid.  Blow some cigarette smoke into the controller. If 
the other RED LED lights up, the relay triggers on the oxidizing lamp (all UVV). This sequence 
reproduce itself every minute or so. When there is no more smoke (VOC), the RED LED is turned 
off at the same time as the lamp. 

 

MAINTENANCE INSTRUCTIONS 

 

MONTHLY:

 Change the pre-filters that protects the motor (part # MSCFTR2) to ensure the 

optimal performance of the unit. Check the lamps: if there is a cloudy residue please clean then 
off with denatured alcohol. 

 

YEARLY

: Change lamps (parts -see below) to maintain performance: make sure to put the same 

lamp in the same clamp. Do not interchange the lamps as the blue end cap lamp works only with 
the VOC controller. 

o

 

LMPHGXJ160-8   

lamp UVC/UVV 

6’’ exposed

 (yellow end cap)  

o

 

LMPHXJ160 

 

 lamp all UVV (blue end cap)  

 

3-5 years

: Change VOC controller board  

 

setting screw: 

triggers at  

 3.4 V DC 

Positive 

 

Neutral  

 

Sensor

 

Summary of Contents for S1000

Page 1: ... One 1 VOC controller part MSC1A factory s pre set Four 4 replacement pre filters part MSCFTR2 LAMP INSTALLATION this step can be done later 1 Open the front door on the S1000 unit 2 Open the door access to the aluminum box by removing the two wing nuts see picture aside 3 Remove the BLUE END CAP LMPHXJ160 lamp from packaging Use the gloves provided 4 Identify the ballast showing LMPHXJ160 follow ...

Page 2: ...it works IMPORTANT you may have to calibrate the VOC Monitor refer to the monitor instructions or call Sanuvox WORKING INSTRUCTION The VOC controller analyzes the air every 90 seconds A 20 foot power cord connects it via a relay to the device to activate the second oxidizing lamp on demand The S1000 VOC unit runs continuously so its regular lamp purifies the air constantly This dual zone lamp UVC ...

Page 3: ...nic board initializes itself 2 After 5 minutes the GREEN LED will turn solid Blow some cigarette smoke into the controller If the other RED LED lights up the relay triggers on the oxidizing lamp all UVV This sequence reproduce itself every minute or so When there is no more smoke VOC the RED LED is turned off at the same time as the lamp MAINTENANCE INSTRUCTIONS MONTHLY Change the pre filters that...

Page 4: ... it via a relay to the device to activate the second oxidizing lamp on demand The S1000 VOC unit runs continuously so its regular lamp purifies the air constantly This dual zone lamp UVC UVV is enough when there are only one or two smokers However if there is much smoke in the room the VOC controller that samples the air on a regular basis will then trigger the second all UVV lamp for a period of ...

Reviews: