background image

5

Wall Plate Template

 

Wall Plate

Lag Bolts

Washers

15

14

16

x4

17

x4

Concrete Installation Kit CMK1 (NOT INCLUDED)

Parts and Hardware for STEP 2

5/16 x 2¾ in.

5/16 x 2¾ in.

 .695 x .350 x .075 in.

.695 x .350 x.075 in.

.695 x .350 x.075 in.

5/16 x 2¾ in.

5/16 x 2¾ in.

Contact Customer Service at 1-888-333-9952 to have these additional pieces shipped directly to you.

Fischer UX 10 x 60 Anchor

x4

x4

x4

x1

x1

Summary of Contents for F55b

Page 1: ...Scan for easy install video san us 253 F55b INSTRUCTION MANUAL We ll Make It Stress Free If you have any questions along the way just give us a call 1 888 333 9952 We re ready to help ...

Page 2: ...e doubts about the safety of the installation assembly or use of this product contact Customer Service at 1 888 333 9952 UK 0800 056 2853 1 2 3 4 What is your wall made of Perfect Unsure Drywall with wood studs Solid concrete or concrete block Call 1 888 333 9952 UK 0800 056 2853 Call 1 888 333 9952 UK 0800 056 2853 CAUTION Avoid potential personal injuries and property damage This product is desi...

Page 3: ...3 Dimensions in cm 25 4 64 5 3 9 9 9 15 9 40 5 1 0 2 5 UP TO 26 6 67 5 3 4 8 5 OFFSET 28 1 71 4 17 2 43 7 6 5 16 6 ...

Page 4: ...d If any parts are missing or damaged do not return the damaged item to your dealer contact Customer Service Never use damaged parts Parts and Hardware for STEP 1 NOTE Not all hardware included will be used M6 x 12mm M8 x 16mm M6 x 20mm M8 x 20mm M6 x 35mm M8 x 35mm 03 04 06 05 07 08 09 x4 x4 x4 x4 x4 x1 x1 x4 TV Screws 10 x4 x4 M5 x 12mm M5 x 35mm Washers M5 M6 M8 11 12 x4 x4 Spacers 13 x4 ...

Page 5: ...t CMK1 NOT INCLUDED Parts and Hardware for STEP 2 5 16 x 2 in 5 16 x 2 in 695 x 350 x 075 in 695 x 350 x 075 in 695 x 350 x 075 in 5 16 x 2 in 5 16 x 2 in Contact Customer Service at 1 888 333 9952 to have these additional pieces shipped directly to you Fischer UX 10 x 60 Anchor x4 x4 x4 x1 x1 ...

Page 6: ... to the wall use the shorter screws a Use the spacers and longer screws b to accommodate Round irregular back TVs TVs with inset mounting holes Extra space needed for cables M6 M5 M8 Too Short Too Long CAUTION Verify adequate thread engagment with the screw or screw spacer combination Too short will not hold the TV Too long will damage the TV Correct Standard configurations are shown For special a...

Page 7: ...ations are shown For special applications or if you are unsure about your hardware selection contact Customer Service a Flat Back b Round Back Extra Space 13 03 04 05 06 07 11 11 12 12 08 09 10 01 02 IMPORTANT After attaching the brackets adjust the straps so they are level with the bottom of the TV ...

Page 8: ...2 mm nominal 1 x 3 in 38 x 89 mm Minimum horizontal space between fasteners 16 in 406 mm 1 Locate your studs Verify and mark the center of the stud by finding the stud edges using an awl a thin nail or an edge to edge stud finder 2 Position the wall plate template 14 at your desired height and line up the holes with your stud center line Level the template and tape in place 2 1 Min 16 in 406 mm Ma...

Page 9: ...to drill into the center of the studs IMPORTANT Pilot holes must be drilled to a depth of 3 in 75 mm 4 Install wall plate assembly 15 using four lag bolts 16 and four washers 17 Tighten the lag bolts only until they are pulled firmly against the wall plate CAUTION Improper use could reduce the holding power of the lag bolt DO NOT over tighten the lag bolts ...

Page 10: ...asteners 16 in 406 mm 1 Position the wall plate template 14 on the wall at your desired height Level the wall plate template and mark the hole locations 2 Drill three pilot holes using a 3 8 in 10 mm diameter masonry drill bit IMPORTANT Pilot holes must be drilled to a depth of 3 in 75 mm Never drill into the mortar between blocks 2 1 Min 16 in 406 mm 3 8 in 10 mm 3 in 75 mm Concrete Installation ...

Page 11: ...wall plate 15 using four lag bolts and four washers use only the lag bolts and washers from the Concrete Installation Kit Tighten the lag bolts only until the washers are pulled firmly against the wall plate CAUTION Improper use could reduce the holding power of the lag bolt DO NOT over tighten the lag bolts Contact Customer Service at 1 888 333 9952 to have the Concrete Installation Kit shipped d...

Page 12: ...P 3 Attach TV to Wall Plate HEAVY You may need assistance with this step IMPORTANT You will hear an audible click when the TV bracket is securely fastened to the wall plate 15 02 01 15 01 02 02 01 15 15 02 01 ...

Page 13: ...ustments REMOVING THE TV Pull down on the straps and lift the TV up and out away from the wall plate LEVEL ADJUSTING THE LEVEL If needed tighten one of the screws on the top of the TV bracket to level the TV ...

Page 14: ...ido 0800 056 2853 para encontrar un soporte compatible Listo para comenzar Lea estas instrucciones en su totalidad para estar seguro de sentirse cómodo con este fácil proceso de instalación Consulte también el manual del usuario de su televisor para ver si existe algún requisito especial para instalar su televisor en la pared Si no entiende las instrucciones o si tiene dudas acerca de la seguridad...

Page 15: ...l televisor Piezas y elementos de sujeción suministrados PASO 1 Colocar la placa de sujeción en el televisor Dimensiones Ver página 3 Ver página 4 Ver página 6 1 1 Seleccione el diámetro de los tornillos para el televisor 1 2 Seleccione la longitud de los tornillos para el televisor 1 3 Fije los soportes para televisor Enrosque manualmente los tornillos en los encastres roscados del dorso del tele...

Page 16: ...a mural 14 IMPORTANTE Asegúrese de perforar el centro del montante IMPORTANTE Los orificios guía deben realizarse hasta una profundidad de 75 mm 3 4 Instale el módulo de la placa mural 15 usando cuatro tornillos tirafondo 16 y cuatro arandelas 17 Ajuste los tornillos tirafondo solamente hasta que queden firmes contra la placa mural PRECAUCIÓN El uso indebido podría reducir la capacidad de retenció...

Page 17: ...ofundidad de 75 mm 3 Nunca perfore el cemento que une los bloques 3 Retire la plantilla de la placa mural 14 e introduzca cuatro anclajes Fischer UX 10 x 60 incluidos en el Kit de instalación en hormigón CMK1 PRECAUCIÓN Cerciórese de que los anclajes queden nivelados respecto de la superficie de hormigón 4 Instale el módulo de la placa mural 15 usando cuatro tornillos tirafondo y cuatro arandelas ...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...hout notice or obligation of any kind Milestone makes no representation of warranty expressed or implied regarding the information contained herein Milestone assumes no responsibility for accuracy completeness or sufficiency of the information contained in this document 2014 Milestone AV Technologies All rights reserved Sanus is a division of Milestone All other brand names or marks are used for i...

Reviews: