Santoemma Sabrina-Foam-Light Using And Maintenance Manual Download Page 8

completely by letting the pump work and keeping the spray lever pressed. 

This operation is useful to clean the hydraulic circuit of the machine, including 

the pump, the couplings, the nozzle. 

2.  After each use, switch off the motor and the pump, then close the security 

valve of the air outlet. 

3. Periodically clean the water filter, removing it from the machine and rinsing it 

under water. 

4.  Periodically check and clean the filter of the vacuum motor, which is located 

between the 2 tanks. 

5.  Eliminate the lime that, in the long run, deposits in the hydraulic circuit, by 

putting a special anti-lime chemical in the solution tank and letting it work from 

some hours. Use the same products used for dishwashers. Empty and then 

rinse the solution tank. This operation should be done every 6-8 months. 

6.  Periodically bring the machine to a technical service point, to check the 

correct working of all the parts subject to wear. In particular: pump, vacuum 

motor and compressor. There are some parts, like carbon brushes, bearings, 

and so on, which must be replaced on time to avoid serious damages to the 

components upon which they are assembled. These damages cannot be then 

covered by warranty. 

7.  Periodically drain (every 2-3 months) the air tank from condensate that may 

originate during the normal working. 

 

ATTENTION: 

This operation must be done with the compressor completely 

empty and with the machine switched off. 

 

 

Summary of Contents for Sabrina-Foam-Light

Page 1: ...r with a special detergent T FOAM Unlike a normal solution of water and detergent this foam does not penetrate in the depth of the textile but acts only on the superficial layer just where the dirt is...

Page 2: ...ntrol panel for the pump and the motor The air compressor and the compressed air tank located in the lower part The control panel for the regulation of foam The coupling for the incoming compressed ai...

Page 3: ...am and then the hand tool to the vacuum hose 5 Raise the recovery tank after releasing the lateral hooks fixing it to the lower tank 6 Put some fresh or warm water into the solution tank through the c...

Page 4: ...ary for the production of foam directly form the external compressor NOTE Please check that the compressor connected to the machine is able to provide the quantity of foam needed by the machine withou...

Page 5: ...Motor Switch Interruttore Pompa Air Input Pressure regulation Manometer Foam outlet Pump outlet Regulation panel Control panel Pump Switch...

Page 6: ...not spray and vacuum foam at a time By doing so the foam could be sucked by the motor and this could cause a damage You have to wait some seconds about 20 or 30 in order to be able to vacuum foam In...

Page 7: ...er 3 bars can generate a too liquid foam while pressure values higher than 3 bars can generate a too dry foam If for any reason the regulation of the pressure in your machine should change you can res...

Page 8: ...l in the solution tank and letting it work from some hours Use the same products used for dishwashers Empty and then rinse the solution tank This operation should be done every 6 8 months 6 Periodical...

Reviews: