ASSEMBLY INSTRUCTIONS
SINUS PENTA
MODULAR INVERTERS
40/
47
2.6.2.
C
ONFIGURATION FOR
ES842
Make sure that the jumpers on the ES842 board are properly set up:
JUMPER
J8, J9, J14
J7, J10, J11
J4, J15, J22
J2, J16, J21
J3, J18, J17
Inverter
configur.
Power supply
unit 1
Power supply unit
2
Leg
“U”
Leg
“V”
Leg
“
W
”
Fitted
Not
fitted
Fitted
Not
fitted
Fitted
Not
fitted
Fitted
Not
fitted
Fitted
Not
fitted
Jumper
status
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
JUMPER
J6
J12, J13, J19, J20, J23
Inverter configur.
Brake Legs
Control board
Fitted Not fitted
Fitted
Jumper status
OFF
ON
ON
IMPORTANT:
“Power supply unit
1
” and
“Power supply unit
2
” of serial ports
CN4 and CN3 stand for:
CN4
–
Power supply unit 1: The first power supply unit in the chain (FIRST Power Supply 1), set up as the
Master (maximum number: 3 cascade-connected power supply units for Sizes S80-S90)
CN3
–
Power supply unit 2: The first power supply unit in the second chain for sizes greater than S90.
The configuration of this inverter will be the same as the FIRST Power supply 1 set up as the Master.
2.6.3.
C
ONFIGURATION FOR
ES887
Make sure that the switches and the jumpers on the ES887 board are properly set up:
SW1&SW2
Leg 1
Leg 2
Leg 3
Fitted
Not fitted
Fitted
Not fitted
Fitted
Not fitted
1 = OFF
4 = OFF
1 = ON
4 = ON
2 = OFF
5 = OFF
2 = ON
5 = ON
3 = OFF
6 = OFF
3 = ON
6 = ON
SW3
1 Leg fitted
1 = OFF
2 = OFF
2 Legs fitted
1 = OFF
2 = ON
3 Legs fitted
[default]
1 = ON
2 = ON
Inverter Size
J2, J3, J4 Current LEM full-scale value (2.5V)
1296
[Dual inverter modules]
ON
4800 A/2
2076
[Triple inverter modules]
OFF
6000 A/3