INSTALLATION INSTRUCTIONS
FLUSH BOTH SUPPLY LINES BEFORE INSTALLATION
.
AFTER FLUSHING , SHUT OFF BOTH SUPPLY LINES.
MINIMUM HOLE SIZE FOR THE HANDLE TRIMS IS 1 5/8” AND MAXIMUM OF 1 3/4”
INSTALLATION INSTRUCTION
INSTALLING THE VALVE WITH THE TRIM
1-
Install the valve onto the wall with at least 2-
3
/
4
” space
between the center of the valve inlet and the finished wall.
2- Screw the extension all thread and stem onto
the valve making sure it is all the way in.
3- Mark the extension all thread flushed to the wall,
remove it and cut.
Do the same with the stem but this time cut 1/4"
less than the extension thread in order to attach
handle.
PAGE 02
STEM
2-
3
/
4
" - 3-
3
/
4
"
c
enter of IN port
EXTENSION
ALL THREAD
CUT EXTENSION
ALL THREAD AND
STEM FLUSH TO WALL
FINISHED WALL
CUT STEM 1/4"
SHORTER FOR HANDLE
INSTALLATION
CUT FLUSH TO
WALL
1/4" SHORTER
THAN ALL THREAD
4- Cut off the excess All Thread and Stem
(remember to cut the Stem 1/4" shorter)
TEST FOR PROPER FUNCTION BEFORE CLOSING WALLS!