background image

21

Warranty

Santak Corp. offers the buyer and the client (hereinafter referred to as 'the
Buyer') the following limited warranty for repair:

Starting from the initial date when the Buyer purchases the product from
Santak or the distributor/the retailer of Santak, the Uninterruptible Power
System and its components related to this 'User's Manual' will not be
short of materials and services under normal use, service and mainte-
nance within three years.  The foregoing warranty card is the only accept-
able warranty card unless  other reasonable  commercial agreements
with specified purposes have been reached.  In certain places where
local laws have special provisions for the term of warranty, the foregoing
term shall not be applicable.  This warranty offers special legal rights.
You are able to obtain other different rights pursuant to local laws. The
Buyer is responsible for certain service and maintenance expenses. The
following situation is not covered by the warranty:  finished goods lost or
serial number  manipulated, loss  or damage due  to force  majeure or
external reasons, misuse, accident, negligence, unauthorized alteration
or repair, overuse, violation of operation stipulations.

Warning: The warranty does not cover any loss caused by the over dis-
charge of the battery.  In order to prevent over discharge, when utility
power supply is cut off, do not keep the UPS working in battery mode for
more than two days without recharging of the battery.  Moreover, the bat-
tery should be charged again at the interval of 4 to 6 months.

Appendix 3. Warranty

Within the warranty period of three years, in case if any damage of the
machine is covered by the warranty, Santak shall offer repair or replace-
ment according  to its own  means.  In case  of need for  the warranty
service, please contact your local Santak Service Center.  The transpor-
tation charges shall be borne by the buyer.

Summary of Contents for Castle C10K(E)

Page 1: ...Uninterruptible Power Systems CASTLE SERIES C6K e C6KS e C10K e C10KS e USER MANUAL...

Page 2: ...ings and operating instructions in this manual and on the unit strictly Keep this manual properly for fu ture reference Do not operate this unit until reading through all safety information and operat...

Page 3: ...2 2 Input and output power wiring and protective earth installation 2 3 Operating procedure for connecting the long backup time model UPS 3 Operation and operating mode 3 1 Operation 3 2 Operating mo...

Page 4: ...to the following models 1 1 System and model description 1 Brief introduction 1 The C6K e is a standard model with inbuilt battery 2 The C6KS e is a long backup time model which is able to connect wit...

Page 5: ...er Terminal Block Intelligent slot External battery Cable tying BACK VIEW of C6K e C6KS e RS232 Fan Input breaker TB cover Terminal Block Intelligent slot External battery socket Cable tying BACK VIEW...

Page 6: ...ncy Hz 1 Brief introduction 6kVA 4 2kW 6kVA 4 2kW 10kVA 7kW 10kVA 7kW C6K e C6KS e C10K e C10KS e 105 130 load transfers to bypass mode after 10 minutes 130 load transfers to bypass mode after 1 secon...

Page 7: ...ersonnel For safety please cut off the mains power breaker before installation The battery breaker also needs to be cut off if it is a long backup time model S model 1 Open the terminal block cover lo...

Page 8: ...current protective breaker at the output power distribution panel of the UPS if necessary 8 To connect the load with the UPS please turn off all the loads first then perform the connection and finally...

Page 9: ...PS with the external battery Otherwise you may encounter the hazardous of electric shock 1 A DC breaker must be connected between the battery pack and the UPS The capacity of breaker must be not less...

Page 10: ...nnect any loads to the UPS now You should connect the input power wire to the right position first And then set the breaker of the battery pack in the ON position After that set the input breaker in t...

Page 11: ...mal the UPS will operate in battery mode without output interruption of the UPS 2 Turn on the UPS with no utility power supplied in Battery mode 3 Turn off the UPS with utility power supplied in Line...

Page 12: ...power mode The display panel in utility power mode is shown in the following diagram The utility power LED and the INV LED are turned on The load level LEDs will be turnd on in accordance with the loa...

Page 13: ...apacity Note that the load level LEDs in utility power mode will indicate the level of the battery capacity in battery mode instead 1 When the UPS is running in battery mode the buzzer beeps once ever...

Page 14: ...ge or fre quency of the utility power has exceeded the normal range of the UPS 2 Other indications on the display panel are the same in utility mode 3 The UPS does not have the backup function when it...

Page 15: ...battery pack capacity and the load level as well as other factors The backup time of standard model may vary from different models and load level Please refer to the following Discharging Time min Di...

Page 16: ...ty bit None RS232 Interface pin number 3 2 5 Function description Rx Tx Ground I O Input Output Ground Optional AS400 interface This optional AS400 card provides dry contact closure signal OPEN or CLO...

Page 17: ...gions of hot climates the battery should be charged and dis charged every 2 months The standard charging time should be at least 12 hours Under normal conditions the battery life lasts 3 to 5 years In...

Page 18: ...Make sure that there is no voltage before touching the batteries The bat tery circuit is not isolated from the input potential circuit There may be hazardous voltage between the battery terminals and...

Page 19: ...UPS Please contact the distributor or ser vice center Please contact the distributor or ser vice center Turn off the UPS Remove all the loads Ensure that the load is not failed or the UPS has no inter...

Page 20: ...ition Please contact the distributor or ser vice center Check the battery or recharge the battery Press the ON button for more than 1 second Replace the batteries Please contact the distributor to obt...

Page 21: ...hat the loading current is supplied directly from the utility power Utility power LED green LED Whenever the utility power LED is turned on it shows that the utility power is normal INV LED green LED...

Page 22: ...61 80 Battery capacity 41 60 Battery capacity 21 40 Battery capacity 0 20 Battery capacity 96 105 Load capacity 76 95 Load capacity overloaded in utility mode and UPS still in INV mode overloaded in...

Page 23: ...warning 1 2 3 5 6 7 8 9 10 4 Over temperature Continuously beep Inv abnormal Continuously beep Continuously beep BUS voltage abnormal Charger and battery failed 21 25 23 24 20 BAT SCR failed Fan abno...

Page 24: ...ocal laws The Buyer is responsible for certain service and maintenance expenses The following situation is not covered by the warranty finished goods lost or serial number manipulated loss or damage d...

Page 25: ...22 614 06745 00...

Reviews: