Page 13
10. Maintenance
In order to guarantee the operability and safety of LIFTKAR, it is recommended to have a
check made by trained personnel once a year, if the LIFTKAR is regularly used.
A) Lubrication chart
1. Rod-end bearing at the crank drive
2. 2 pieces of main wheels
B) Chain drive
1. Check the tension of the chain.
Lubricate the chain only slightly with chain grease.
(Do not use oil because the oil could reach the sliding clutch,
this would cause a decrease of the torque.)
C) Check of the coal brush
D) Battery check
on damages of the covering.
10.1. Directions for using the batteries:
The batteries of the stairclimber are completely closed, maintenance-free gel-
sealed lead batteries.
2 units with 12 V each connected in series.
Recycling like car batteries.
Note:
The battery is lasting very long, if you pay attention to the following:
•
Charge the battery unit after each use.
•
Use only the original battery chargers. These are charging with the right tension
and current Overcharging is not possible with these battery chargers.
•
If the stairclimber is not used for a longer time, charge the battery unit at least
once a month.
•
Never discharge the battery unit completely. In case of a decrease of capacity,
take a full-charged battery unit for further working. Charge the discharged
battery unit immediately.
•
The best temperature for charging is room temperature.
•
Keep the battery unit dry and cool.