background image

 

 

 

OPERATION MANUAL FOR GAUGE UNIT

 

 

ZM600 

 

 
 

 

Sanmenxia ZhongyuanJingmiCo.,Ltd

 

 

Summary of Contents for ZM600

Page 1: ...OPERATION MANUAL FOR GAUGE UNIT ZM600 Sanmenxia ZhongyuanJingmiCo Ltd ...

Page 2: ... the READY signal has gone off Heavy load or strong force can deform the covers of control unit Do not stand or step on the cover of the unit For the sake of safety the power supply and the grounding wire of each component must be grounded and the control instrument is connected to the screw on the right side of the switch Operation conditions must be 1 Operation temperature 0 40 2 Humidity Less t...

Page 3: ...ONTENTS 1 Introduction 1 2 Features 2 3 Extension Function 3 4 Interface 3 4 1 Measuring Interface 4 4 2 Setting Interface 6 4 3 Adjustment Interface 7 5 I O Interface And Connection 8 6 Method Of Use 11 ...

Page 4: ...ocessed or after the size of the workpiece with electric sensor for measurement if the use of air momentum meter for measurement it needs to be measured through the pneumatic probe and AE converter The measurement results are displayed on the LCD touch screen and the control signal is sent to the machine at the preset size It has better man machine effect and more intuitive measurement status disp...

Page 5: ...e sending a signal to control the movement of the machine 2 Convenient and compact Using 4 3 inch TFT touch screen LCD display embedded installation low power design Saving installation space energy saving and environmental protection 3 Good human interface The display interface is more intuitive and clear the display content is more rich and comprehensive and the operation is simpler and faster 4...

Page 6: ... the discontinuous surface can set memory function such as maximum memory 3 BCD Binary The digital interface to the machine tool 4 Standard dual channel sensor input 4 Interface Instructions Z600 type active grinding measuring instrument is divided into three function Windows measuring setting and adjusting The system defaults into the measurement module Click the button to enter the setting windo...

Page 7: ...ayed in digital form Instruction Displays the measured value of the measured item Display signal points Displays the adjustment value of the corresponding measurement item of the channel Adjustment range 60μm M1 adjusts sincrease M1 adjust decreases Click the button switch to M2 add and subtract Click the button switch to M1 add and subtract ...

Page 8: ...acturing deviation The actual size of standard parts isφ50 009 When the null position of M1 is set with this standard component the deviation between the actual value and the theoretical value is 1μm it is necessary to conduct supplementary adjustment Click Type 1 or click M1 Set the tuning value to 1 to compensate the standard parts After setting M2 to zero click first switch to the M2 tuning int...

Page 9: ...k the number section and the keyboard pops up for setting Instruction P1 Signal points of rough grinding P2 Signal points of fine grinding P3 Light grinding signal points P4 The signal point of retreating knife Signal point setting value P1 P2 P3 P4 SCUT The reverse cut value ...

Page 10: ...g Reset value the compensation value of the probe by the system after resetting Multiplier the probe amplification ratio can be set through the pop up keyboard The factory has been set the standard value is 1 the user does not need to adjust Adjustment is required only when changing the length of measuring device or rod Reset button press once to reset the displayed value press again to restore th...

Page 11: ... of measurement BCD 1 Pink1 O1 P1 M1P1 P1 M1P1 2 Pink2 O2 P2 M1P2 P2 M1P2 3 Pink3 O3 P3 M1P3 P3 M1P3 4 Pink4 O4 P4 M1P4 P4 M1P4 5 Pink5 O5 M2P1 NG M2P1 6 Pink6 O6 M2P2 OK M2P2 7 Pink7 O7 M2P3 OK M2P3 8 Pink8 O8 M2P4 OK M2P4 9 Pink9 O9 M2 NG BCD1 M1 M2BCD1 10 Pink10 O10 BCD2 M1 M2BCD2 11 Yellow1 O11 BCD4 M1 M2BCD4 12 Yellow2 O12 BCD8 M1 M2BCD8 13 Yellow3 O13 BCD1 10 M1 M2BCD1 10 ...

Page 12: ...ow7 O17 BCD1 100 M1 M2BCD1 100 18 Yellow8 O18 BCD2 100 M1 M2BCD2 100 19 Yellow9 24V 20 Yellow10 O19 BCD4 100 M1 M2BCD4 100 21 Green1 O20 confirm actuatin g BCD8 100 M1 M2BCD8 100 22 Green2 O21 Output is negative Output is negative 23 Green3 RES 24 Green4 SWD 25 Green5 SWC 26 Green6 485A 27 Green7 485B 28 Green8 COM OUT ...

Page 13: ...t M2 35 Gray5 GND 36 Gray6 COMIN 37 Gray7 0V The I O parameters Power 24V DC 20 10W 24V and 0V are respectively connected to the output line yellow line 9 and gray line 7 Grounding connect the ground wire of the machine tool to the screw of the grounding terminal on the right side of the switch Output signal optical relay 200mA 24VAC DC Input signal optocoupler 24V 5mA ...

Page 14: ...indow the interface displays G1 records the size of the display value adjusts the lower contact makes the display value change to about half of the initial value locks the lower contact and then continues to adjust the upper contact Change the display value to about 0 within 30 lock the upper contact At this point click the display value changes to 0 the probe compensation value enters the reset v...

Page 15: ...he boot screen and press the button below the screen or set the display value after compensation to 0 Adjust the contact away from the measuring surface Click the system enters the adjustment window the interface displays G1 records the display value adjusts the lower contact to make the display value change to about 0 the value is within 30 and locks the contact At this point click the display va...

Page 16: ...h of the measuring device or measuring rod Adjust the upper and lower contact away from the measuring surface Click the system enters the adjustment window and the interface displays G1 Adjust the lower contact so that the display value is about 0 value within 30 Click the display value is 0 Insert a 0 05mm feeler between the contact and the measuring surface and record the display value Click Jum...

Page 17: ...V1 1 20210930 Sanmenxia ZhongyuanJingmiCo Ltd Address east section of weiliu road sanmenxia industrial park henan China Tel 0398 2751818 Fax 0398 2751819 Postcode 472000 http www zyjm com ...

Reviews: