6 –
Assemble the temporary panel to the box.
7 –
Once the works on electricity, plumbing and tiles
have been finished, cut the temporary protective
cover at the proper mark at the wall level.
(see picture)
8 –
Insert the wall rosette through the base and pass the
cables from the spout through the rosette.
9 –
Connect the cables from the spout to the cables
coming from the cables sleeve.
10 –
Fix the rosette to the base with the 2 provided
screws.
11 –
Connect the electronic unit’s connector coming
from the cables sleeve to the power splitter solenoid’s
connector.
(see picture)
12 –
Connect the cables from the power splitter leading
to the solenoids to the solenoid’s connectors.
Fix the Tubular spout by inserting the nipples from the
base.
Make sure that this area is clean before proceeding.
Important:
This product includes a self adjusting sensor.
The ideal sensor range for the specific location will be set
automatically.
Check that no objects are in front of the sensor besides the
washbasin. Remove now the protecting sticker that covers
the sensor.
//
MIXER INSTALLATION
Secure the screw with the Allen key. Make sure that the
aerator at the spout faces the washbasin.