To connect a bathtub (or shower), make sure the waste 
trap height is raised by at least 15cm above floor level.

  

Connection must be made using 40mm or 50mm 
diameter pipework, with minimum slope of 1%.

The disposal of waste from the Sanicom can discharged through a 32mm diameter copper or plastic pipes (or PVC, ABS, etc.).

This discharge pipe must be designed so as to prevent back-flow from the sewers. See diagram above.

Horizontal discharge pipework should maintain a 1% fall (1cm/M) to the soil and vent pipe. If a vertical rise is required, this must be installed at 
the start of the run, before the horizontal section. The horizontal section should then have a minimum 1% fall to the final drain point.

Take care that the discharge valve flap faces the direction of flow.

If the end of the discharge pipework is much lower than the unit, install a riser pipe about 80mm long from the highest point of the discharge 
run and fit an air admittance pipe on top (capable of withstanding at least 15psi pressure.) to break the syphon.

The discharge should be connected to a 100mm discharge stack via a strap boss connector.

9. Connection to sanitary ware

10. Connection to soil and vent pipe or drain

150mm min

1%

40mm

32mm

2.5%            

2.5%            

Summary of Contents for Sanicom FF03-P95

Page 1: ...e safety of persons Indication that a risk of electrical origin exists Electrical installation must be carried out by a professional electrician Attention Failure to comply with this instruction could endanger the safe functioning of the apparatus 2 List of Accessories included 25 x 40 A B C D E F G H I x2 x1 x2 x2 x1 x1 x2 x2 x1 Hose clip Hose clip Inlet Cover Hose clip Screw Plug Elbow Hose clip...

Page 2: ...aste enters the unit As soon as the waste enters the tank the pump starts 5 Performance Curve Height and Length of the discharge pipe Flow Rate litre min Vertical Height Metres 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 12 11 10 9 8 7 6 5 4 3 2 1 0 max 10m 3 7 4m 3m 2m 1m 5m 6m 7m 1 Max 8m max 20m max 30m max 40m max 50m max 60m max 70m max 80m 420mm 330mm 490mm ø 60 230mm ...

Page 3: ... Maximum current consumption 3 3 A Electrical class I Protection index IP44 Max temp with intermittent functioning 80 Net weight 10 kg In the case of bath or shower tray make sure the waste traps are raised 15cm above floor level CAUTION 1 All applications other than those described in this notice are prohibited 2 Do not exceed an incoming flow rate greater than 80 of the flow rate stated on the d...

Page 4: ...a vertical rise is required this must be installed at the start of the run before the horizontal section The horizontal section should then have a minimum 1 fall to the final drain point Take care that the discharge valve flap faces the direction of flow If the end of the discharge pipework is much lower than the unit install a riser pipe about 80mm long from the highest point of the discharge run...

Page 5: ...ronic circuit board On this card use the point marked E V and the unused neutral connection point marked N Use a round 2 x 0 75mm 2 wire which must pass across the lid of the upper casing through the cable gland before being connected to the chosen alarm system The electrical installation should be carried out by a qualified person All wiring must conform to BS7671 1992 requirements for electrical...

Page 6: ...s Pump is blocked Pump Jammed To much water flowing through Call a service engineer Call a service engineer Reduce water inflow ELECTRICAL INSTALLATION MUST BE CARRIED OUT BY A PROFESSIONAL ELECTRICIAN Before carrying out any service work always disconnect power supply SYMPTOMS PROBABLE CAUSES REMEDIES Motor does not start Pressure reader tube kinked or out of position Electronic card defective Ch...

Page 7: ...19 Parts ...

Reviews: