6. Technical Data & Application

7. Installation

 FITTING

The Sanicom can be fixed to the floor, preventing it from 
turning or moving.

1.

 

Warning:

 The space in which the Sanicom is installed 

must be large enough to leave at least 600mm around 
the unit for easy maintenance. This space must be 
well lit, ventilated, and must never be immersed in 
water and must be protected from frost.

2.

  Isolation valves should be fitted to the inlet pipework 

and discharge pipework to isolate the unit in case of 
the need for service.

Application

Commercial sink, washing machine, 
dishwasher or shower* or bath*

Type

FF03-P95

Maximum vertical pumping height

8m

Voltage

220 – 240 V

Frequency

50 Hz

Maximum power consumption

750 W

Maximum current consumption

3.3 A

Electrical class

I

Protection index

IP44

Max temp with intermittent functioning

80°

Net weight

10 kg

* In the case of bath or shower tray, make sure the waste traps are raised 15cm above floor level.

CAUTION:  1.

 All applications other than those described in this notice are prohibited.

 

2.

 Do not exceed an incoming flow rate greater than 80% of the flow rate stated on the design curve in any of the apparatus.

8. Connection to side inlets

Use the flexible inlet connector (

A

) for side inlet 

connections. Using a metalwork saw, saw off the desired 
inlet point, remove any burrs and then fix the flexible 
inlet connector with the hose clip (

D

).

We recommend the installation of a grease trap for 
installations with a high grease inflow.

Connection to the inlet can be made using a 40mm or 
50mm pipe. To make a 50mm connection, cut off the 
end of sleeve (

A

) beforehand.

H

H

G

G

I

C

A

D

Summary of Contents for Sanicom FF03-P95

Page 1: ...e safety of persons Indication that a risk of electrical origin exists Electrical installation must be carried out by a professional electrician Attention Failure to comply with this instruction could endanger the safe functioning of the apparatus 2 List of Accessories included 25 x 40 A B C D E F G H I x2 x1 x2 x2 x1 x1 x2 x2 x1 Hose clip Hose clip Inlet Cover Hose clip Screw Plug Elbow Hose clip...

Page 2: ...aste enters the unit As soon as the waste enters the tank the pump starts 5 Performance Curve Height and Length of the discharge pipe Flow Rate litre min Vertical Height Metres 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 12 11 10 9 8 7 6 5 4 3 2 1 0 max 10m 3 7 4m 3m 2m 1m 5m 6m 7m 1 Max 8m max 20m max 30m max 40m max 50m max 60m max 70m max 80m 420mm 330mm 490mm ø 60 230mm ...

Page 3: ... Maximum current consumption 3 3 A Electrical class I Protection index IP44 Max temp with intermittent functioning 80 Net weight 10 kg In the case of bath or shower tray make sure the waste traps are raised 15cm above floor level CAUTION 1 All applications other than those described in this notice are prohibited 2 Do not exceed an incoming flow rate greater than 80 of the flow rate stated on the d...

Page 4: ...a vertical rise is required this must be installed at the start of the run before the horizontal section The horizontal section should then have a minimum 1 fall to the final drain point Take care that the discharge valve flap faces the direction of flow If the end of the discharge pipework is much lower than the unit install a riser pipe about 80mm long from the highest point of the discharge run...

Page 5: ...ronic circuit board On this card use the point marked E V and the unused neutral connection point marked N Use a round 2 x 0 75mm 2 wire which must pass across the lid of the upper casing through the cable gland before being connected to the chosen alarm system The electrical installation should be carried out by a qualified person All wiring must conform to BS7671 1992 requirements for electrical...

Page 6: ...s Pump is blocked Pump Jammed To much water flowing through Call a service engineer Call a service engineer Reduce water inflow ELECTRICAL INSTALLATION MUST BE CARRIED OUT BY A PROFESSIONAL ELECTRICIAN Before carrying out any service work always disconnect power supply SYMPTOMS PROBABLE CAUSES REMEDIES Motor does not start Pressure reader tube kinked or out of position Electronic card defective Ch...

Page 7: ...19 Parts ...

Reviews: