6. Technical Data & Application
7. Installation
FITTING
The Sanicom can be fixed to the floor, preventing it from
turning or moving.
1.
Warning:
The space in which the Sanicom is installed
must be large enough to leave at least 600mm around
the unit for easy maintenance. This space must be
well lit, ventilated, and must never be immersed in
water and must be protected from frost.
2.
Isolation valves should be fitted to the inlet pipework
and discharge pipework to isolate the unit in case of
the need for service.
Application
Commercial sink, washing machine,
dishwasher or shower* or bath*
Type
FF03-P95
Maximum vertical pumping height
8m
Voltage
220 – 240 V
Frequency
50 Hz
Maximum power consumption
750 W
Maximum current consumption
3.3 A
Electrical class
I
Protection index
IP44
Max temp with intermittent functioning
80°
Net weight
10 kg
* In the case of bath or shower tray, make sure the waste traps are raised 15cm above floor level.
CAUTION: 1.
All applications other than those described in this notice are prohibited.
2.
Do not exceed an incoming flow rate greater than 80% of the flow rate stated on the design curve in any of the apparatus.
8. Connection to side inlets
Use the flexible inlet connector (
A
) for side inlet
connections. Using a metalwork saw, saw off the desired
inlet point, remove any burrs and then fix the flexible
inlet connector with the hose clip (
D
).
We recommend the installation of a grease trap for
installations with a high grease inflow.
Connection to the inlet can be made using a 40mm or
50mm pipe. To make a 50mm connection, cut off the
end of sleeve (
A
) beforehand.
H
H
G
G
I
C
A
D