background image

 

 

16

 

3.1.1 System Status 

The System Status screen: 

 

 

Displays version and temperature information which is important for technical support personnel. 

 

 

 

 

 
 

Summary of Contents for T3 Mux M13

Page 1: ...anual Type the abstract of the document here The abstract is typically a short summary of the contents of the document Type the abstract of the document here The abstract is typically a short summary...

Page 2: ...ates screen menus and parameters indicates keyboard keys Enter q s NOTE Notes inform the user of additional but essential information or features CAUTION Cautions inform the user of potential damage m...

Page 3: ...3 This page is intentionally blank...

Page 4: ...RS232 Port 7 2 3 6 Establishing Terminal Connection 8 2 4 Front Panel 12 2 4 1 DS1 Connectors 12 2 4 2 Push Buttons 13 2 4 3 System Status LED 13 Section 3 User Interface 14 3 1 System Management 15 3...

Page 5: ...which carries up to 45 Mbps of 64 kbps channelized voice channels and rearranges the DS 3 framing into 28 T1 framings The major features of the T3Mux are as follows Cost Effective DS3 bandwidth consol...

Page 6: ...aim immediately with the carrier keep the original packaging for damage verification and or returning the unit and contact Sangoma Customer Service 2 2 Shipping Contents T3Mux unit 5V 2A Power Supply...

Page 7: ...r requiring a straight through cable not null modem Baud rate 115200 8 data bits 1 stop bit no flow control The RS232 port is used for Terminal Connection The Serial connection is established using a...

Page 8: ...Tel exe from ftp ftp sangoma com T3Mux puttytel exe 2 Start PuttyTel exe on you Windows PC 3 Select Serial port settings as shown on this screenshot 4 Initialize the terminal session by clicking on Op...

Page 9: ...9 Alternatively T3Mux can accept Telnet connections over TCP IP...

Page 10: ...10 It is important to select Passive Telnet negotiation mode in Connection Telnet...

Page 11: ...11 Once the configuration options are selected please click Open you should see the Login prompt of the Telnet Server...

Page 12: ...onnector each in a DSX pinout 1 A straight through cable CABL 614G can be used to connect directly to CSU DSU boards such as Sangoma s A108DE 2 A split cable CABL 630 should be used to connect Sangoma...

Page 13: ...a Port is shown as Green when the T1 line is Operational no Alarms The Status of a Port is shown as Red when the T1 line is non Operational there are Alarms To find out what are the Alarms please refe...

Page 14: ...14 Section 3 User Interface This section describes the Menu driven user interface of the T3Mux Here is the structure of Menu tree...

Page 15: ...15 3 1 System Management The System Management menu Used to view system status and change system configuration...

Page 16: ...16 3 1 1 System Status The System Status screen Displays version and temperature information which is important for technical support personnel...

Page 17: ...System Configuration menu Used to set IP Configuration Telnet Password and MAC Address for the LAN Connection The default user name for LAN Connection is admin password sangoma The RS232 Connection do...

Page 18: ...Mask Default Gateway and Primary DNS Server will also be required By default the device is configured with static IP Address of 192 168 10 1 and Net Mask of 255 255 255 0 The NetBIOS Microsoft Network...

Page 19: ...19 3 2 DS1 Interface The DS1 Interface menu Used to view Status of T1 lines configure T1 line s and control the T1 Loopback...

Page 20: ...20 3 2 1 DS1 Status The T1 Status screen Displays an Alarm at T1 level Only the highest severity alarm is shown For example if both LOS and OOF are present only LOS will be shown...

Page 21: ...y except for the Clock option The Clock Source options should be interpreted as follows Normal Clock the clock is delivered from Upstream from DS3 side if the Upstream clock is not available recover t...

Page 22: ...rates how the T3Mux acts as a pass through for T1 Master Clock coming from Upstream T1 Master Clock DS3 T1 Normal Clock Figure 3 2 2 1 3 2 3 DS1 Loopback The T1 Loopback menu Used to view and control...

Page 23: ...When a T1 Local Loopback is enabled all data that is output by the Transmitter will be routed to the Receiver Local Loopback is illustrated on Figure 3 3 3 1 Figure 3 3 3 1 When a T1 Line Loopback is...

Page 24: ...24 3 3 DS3 Interface The DS3 Interface menu Used to view Status of DS3 line configure DS3 and control the DS3 Loopback...

Page 25: ...25 3 3 1 DS3 Status The DS3 Status menu Used to view DS3 Alarms...

Page 26: ...26 3 3 2 DS3 Configuration The DS3 Configuration menu Used to view change DS3 configuration...

Page 27: ...of Local Loopback in Framer Digital Interface 2 Control of Local and Line Loopback in LIU Analog Interface When a Local Loopback is enabled all data that is output by the Transmitter will be routed to...

Page 28: ...ll data that is received will be output to the Transmitter Line Loopback is illustrated on Figure 3 2 3 1 This is the diagram of DS3 Line Loopback in LIU Figure 3 2 3 1 This is the diagram of DS3 Loca...

Page 29: ...u Used to Restore Configuration to its default state both in the volatile memory RAM and in non volatile storage EEPROM The Restart System Module option will restart the firmware so the current settin...

Page 30: ...ent using serial port and you are ready for firmware upgrade To start updating firmware you need to reset or reboot your T3Mux When your T3Mux is boot up the lights of the ports will flash about 10 se...

Reviews: