![Sangean U-3 Service Manual Download Page 9](http://html2.mh-extra.com/html/sangean/u-3/u-3_service-manual_3901267009.webp)
4. ALIGNMENT FOR AM SENSITIVITY
a. Required Instruments
AM Signal Generator
SSVM
b. Alignment Procedure
Mode Adjustment
Procedure
(1) Turn on the radio.
(2) Connect a SSVM to the speaker TP8 and TP9 terminals.
(3) Connect an AM signal generator together with standard loop dummy antenna and
feed 30% modulated signal to the AM ferrite
(4) Tune the generator frequency to 1404 kHz.
(5) Tune the AM frequency to 1404 kHz and adjust TC2 to have a max reading on
SSVM.
(6) Return the generator frequency to 603 kHz.
(7) Tune the AM frequency to 603 kHz and adjust bar antenna to have a max reading on
SSVM.
AM
TC2
Bar Antenna
(8) Repeat (4) to (7) as necessary to minimize tracking error.
c. Instrument Connection
L8
L7
TC2
60 cm
The radio is located
perpendicularly to
the Loop Antenna
Loop Antenna
AM Signal Generator
TP9
TP8
DVM
9
Summary of Contents for U-3
Page 11: ...TEST POINTS DIAGRAM 11...
Page 12: ...MAIN PCB TOP VIEW 12...
Page 13: ...MAIN PCB BOTTOM VIEW 13...
Page 14: ...CONTROL PCB TOP VIEW 14...
Page 15: ...CONTROL PCB BOTTOM VIEW 15...
Page 16: ...POWER PCB VIEW 16...
Page 17: ...WIRING DIAGRAM 17...
Page 26: ......
Page 27: ...IC CIRCUIT BLOCK DIAGRAM 1 IC1 LA1186N 2 IC2 TA2099F 27...
Page 28: ...3 IC3 TDA7266L 4 IC4 TC4066BP 28...
Page 29: ...5 IC5 NJM2100L 6 IC6 IC8 BA 09FP 29...
Page 30: ...7 IC7 XC6366B103 MRNSOT25 8 IC9 XC61CN6002MRN 30...
Page 31: ...9 IC10 XC62FP6002PRN 10 IC201 XC62FP3002PRN 31...
Page 32: ...11 IC200 TC9318AFAG 32...
Page 39: ...SCHEMATIC DIAGRAM 39...