3. ALIGNMENT FOR FM TUNING VOLTAGE
a. Required Instruments
DVM
b. Alignment Procedure
Mode Adjustment
Procedure
(1) Turn on the radio.
(2) Connect the probe of DVM to the TP19 and TP14
(3) Tune the FM frequency to 108MHz.
FM L2
(4) Adjust L2 to have a reading of 8.2V
±
0.2V.
(5) Tune the FM frequency to 87.5MHz.,check and have a reading of 1.9V
±
0.2V
c. Instrument Connection
L2
TP14
TP19
DVM
8
Summary of Contents for U-3
Page 11: ...TEST POINTS DIAGRAM 11...
Page 12: ...MAIN PCB TOP VIEW 12...
Page 13: ...MAIN PCB BOTTOM VIEW 13...
Page 14: ...CONTROL PCB TOP VIEW 14...
Page 15: ...CONTROL PCB BOTTOM VIEW 15...
Page 16: ...POWER PCB VIEW 16...
Page 17: ...WIRING DIAGRAM 17...
Page 26: ......
Page 27: ...IC CIRCUIT BLOCK DIAGRAM 1 IC1 LA1186N 2 IC2 TA2099F 27...
Page 28: ...3 IC3 TDA7266L 4 IC4 TC4066BP 28...
Page 29: ...5 IC5 NJM2100L 6 IC6 IC8 BA 09FP 29...
Page 30: ...7 IC7 XC6366B103 MRNSOT25 8 IC9 XC61CN6002MRN 30...
Page 31: ...9 IC10 XC62FP6002PRN 10 IC201 XC62FP3002PRN 31...
Page 32: ...11 IC200 TC9318AFAG 32...
Page 39: ...SCHEMATIC DIAGRAM 39...