5. ALIGNMENT FOR MW SENSITIVITY
a. Required
Instrument
RF signal generator
SSVM
b. Alignment
Procedure
Mode Adjustment
Procedure
(1) Set the power switch to ON position.
(2) Connect a SSVM to the AF out (TP3 and TP4).
(3) Connect the AM signal generator to the loop antenna
(4) Set signal generator to 600KHz, with 30% modulation set tuning to signal,
and adjust L1 for maximum reading on SSVM.
(5) Set signal generator to 1400KHz set tuning to signal, and adjust TC1 for
maximum reading on SSVM.
MW
L1
TC1
(6) Repeat steps (4) and (5) until best sensitivity is obtained at both frequencies.
c. Instrument
Connection
TC1
L1
50
Ω
(60 cm)
L1
Antenna Bar
Signal Generator
TP3
TP4
SSVM
9
Summary of Contents for MMR-77
Page 4: ...BLOCK DIAGRAM 4...
Page 10: ...TEST POINTS DIAGRAM 10...
Page 11: ...MAIN PCB TOP VIEW 11...
Page 12: ...MAIN PCB BOTTOM VIEW 12...
Page 13: ...CONTROL PCB TOP VIEW 13...
Page 14: ...CONTROL PCB BOTTOM VIEW 14...
Page 15: ...WIRING DIAGRAM 15...
Page 22: ......
Page 23: ...IC CIRCUIT BLOCK DIAGRAM 1 IC1 CXA1619BS 2 IC2 BA10324AF 23...
Page 24: ...3 IC3 XC62AP2002PR 4 IC4 IC101 TC7WH74FK 24...
Page 28: ...SCHEMATIC DIAGRAM 28...