background image

 

USER GUIDE 

 
 

 

www.kontron.com 

 

// 1 

 

KISS 2U Short V3 

KISS 2U Short V3 CFL 

 

Doc. User Guide, Rev. 1.1 

Doc. ID: 1064-5121  

 

 

Summary of Contents for Kontron KISS 2U Short V3

Page 1: ...USER GUIDE www kontron com 1 KISS 2U Short V3 KISS 2U Short V3 CFL Doc User Guide Rev 1 1 Doc ID 1064 5121...

Page 2: ...KISS 2U Short V3 User Guide Rev 1 1 www kontron com 2 This page has been intentionally left blank...

Page 3: ...n will be suitable for the specified use without further testing or modification Kontron expressly informs the user that this user guide only contains a general description of processes and instructio...

Page 4: ...USE OR RESALE FOR THE OPERATION OF APPLICATION IN A HAZARDOUS ENVIRONMENT OR REQUIRING FAIL SAFE PERFORMANCE OR IN WHICH THE FAILURE OF PRODUCTS COULD LEAD DIRECTLY TO DEATH PERSONAL INJURY OR SEVERE...

Page 5: ...ffices contact information on the last page of this user guide or visit our website CONTACT US Customer Support Find Kontron contacts by visiting http www kontron com support Customer Service As a tru...

Page 6: ...escribed by the law may endanger your life health and or result in damage to your material ESD Sensitive Device This symbol and title inform that the electronic products and their components are sensi...

Page 7: ...rounding point shall remain connected The earth ground cable shall be the last cable to be disconnected or the first cable to be connected when performing installation or removal procedures on this pr...

Page 8: ...ame manner as the product was delivered Special care is necessary when handling or unpacking the product Refer to any special handling and unpacking instruction within this user guide Quality and Envi...

Page 9: ...y 16 3 1 Accessories and Spare Parts 16 3 2 Shipment Packaging and Unpacking 16 3 3 Type Label 16 4 Product Description 17 4 1 Front Side 18 4 1 1 USB Ports 20 4 1 2 Controls and Indicators 20 4 1 3 F...

Page 10: ...leaning the Filter Pad 44 10 2 Replacing the Fan Assembly 46 10 3 Replacing the Lithium Battery 47 11 Technical Data 48 11 1 Block Diagrams 48 11 2 Technical Specification 50 11 3 Power Specification...

Page 11: ...rt V3 CFL 26 Figure 16 PSU 400W AC 27 Figure 17 Left side 28 Figure 18 Right side 28 Figure 19 Underside of cover with fixing brackets 29 Figure 20 Configuration with micro ATX mainboard and low profi...

Page 12: ...is available to cool the product ensure that Ventilation openings are not covered or blocked Clean the filter pad regularly as often as necessary depending on the environment Do not place the product...

Page 13: ...power circuits of different devices cause no electrical hazards A sufficient dimensioning of the power cable wires must be selected according to the maximum electrical specifications on the product l...

Page 14: ...s or air ionizers for more protection 3 Always handle electrostatically sensitive components by their edge or by their casing 4 Avoid contact with pins leads or circuitry 5 Switch off power and input...

Page 15: ...ce and performance The KISS 2U Short V3 is designed for high performance reliability and use in in harsh Industrial environments offering total flexibility with installation options in a 19 industrial...

Page 16: ...wer cable 1 With Europe rating other cable ratings are optional Safety instructions 1 Safety Instructions for IT equipment 3 1 Accessories and Spare Parts Table 2 Accessories and spares parts Accessor...

Page 17: ...pped with up to three drive bays where drive bays D1 and D2 are front accessible and drive bay D3 is internal The power button is located on the front side behind the front access panel The LED indica...

Page 18: ...5 Front access panel side plates 6 Kontron logo 7 Mounting holes for 19 racks For use on a desktop remove both handle brackets right side and left side see Chapter 8 2 Removing the Handle Brackets an...

Page 19: ...crews 3 Filter pad holder with filter pad and knurled screw 4 Slot for the locking mechanism 5 Indicators Power LED and HDD LED 6 Cover fastening screw on the front side 7 Power button 8 D1 slim drive...

Page 20: ...the product Pressing the power button for longer than four seconds initiates a forced system shutdown before the power to the product is switched off The power button does not disconnect from the main...

Page 21: ...ts up during hard disk activity 4 1 3 Front Access Panel The securing lock mechanism Figure 7 pos 4 located on the front access panel protects against unauthorized use When locked the front access pan...

Page 22: ...rled screws 2 Connector for fan control 3 2x fans temperature controlled independently from each other 4 Bolt with tapped hole screw 5 Positioning holes for filter pad holder s positioning latches Ope...

Page 23: ...der s positioning latches into the fan assembly s position holes Figure 12 pos 5 and then fastening the filter pad holder s knurled screw Figure 9 pos 3 4 1 6 Drive Bays The KISS 2U Short V3 can be eq...

Page 24: ...on the system configuration Figure 13 Rear side with micro ATX mainboard with riser card 1 Input power socket 2 Power Supply Units PSU ventilation holes 3 Card cage for mainboard board and expansion...

Page 25: ...lation holes 3 Card cage external fastening screws for the mainboard board and expansion cards 4 Mainboard external interfaces 5 Rear side of the cover with three knurled screws 6 Slot brackets for ex...

Page 26: ...inboard interface panel KISS 2U Short V3 CFL 1 Mouse 2 Keyboard 3 4x USB 2 0 4 2x DP V1 2 5 Serial port COM 6 DVI D 7 LAN2 8 2x USB 3 1 Gen 2 Type A 9 LAN1 iAMT 10 2x USB 3 1 Gen 1 Type A 11 Audio jac...

Page 27: ...ible If the end environment restricts access to the power cable disconnection must be guaranteed using a separate cut off fixture Do not disconnect the power from the product while the product is swit...

Page 28: ...ped screw holes Figure 17 Figure 18 pos 1 used for installation in a 19 industrial rack with slide rails Figure 17 Left side Figure 18 Right side 1 4x M4 tapped holes on both sides 2 Card cage for mai...

Page 29: ...us energy To close properly secure the cover knurled screws one front side screw and three rear side screws The cover fixes to the main chassis using fixing brackets on the front side of the cover and...

Page 30: ...w profile expansion cards 1 Cover retaining plate on the front side 2 D1 D2 and D3 drives bays stacked one above the other into a drive cage 3 Power Supply Unit PSU 4 Cover retaining plates on the rea...

Page 31: ...other into a drive cage 3 Power Supply Unit PSU 4 Cover retaining plates on the rear side 5 Interface connectors available externally 6 Fastening screws for riser card retaining bracket 7 Retaining br...

Page 32: ...M2 2280 key M PCIe drive RAID support is not available for the on board M 2 memory module 5 2 Expansion Cards The following slots are available for expansion on the rear side of the chassis Table 6 E...

Page 33: ...sufficient air flows from the front to the back of the chassis ensure that the ventilation holes are not covered blocked or obstructed by surrounding parts Before installing the KISS 2U Short V3 take...

Page 34: ...ded intended used is closed and locked Only when the cover is secured is it ensured that the operator does not have access to the internal parts loaded with hazardous energy To close properly secured...

Page 35: ...ernal components Follow these instructions when handling internal components and observe the corresponding safety instruction included in Chapter 1 General Safety Instructions for IT Equipment Energy...

Page 36: ...nd secure the cover with the knurled screws as described in Chapter 7 1 Opening and Closing the Cover step 5 7 2 2 Installing and Removing Low Profile Expansion Cards To install or remove low profile...

Page 37: ...is well ventilated and does not prevent the KISS 2U Short V3 from taking in air at the front and exhausting air at the rear Do not place the product close to heat sources or damp places Before connect...

Page 38: ...e removable Figure 27 Front access panel side plate with handle bracket 1 Bracket handle 2 Front access panel side plate To remove the front access panel and front access panel side plates proceed as...

Page 39: ...3 If required remove front access panel and the two front access panel side plates as described in Chapter 8 3 Removing the Front Access Panel and Front Access Panel Side Plates 8 5 Installing in a 1...

Page 40: ...Option Kontron offers compatible 19 Slide Rails and Rack Slide Rails Kit for the KISS 2U Short V3 For more information see Table 2 Accessories and spares parts To support the KISS 2U Short V3 s weigh...

Page 41: ...U Short V3 2 Screws attaching slide rail to the chassis 3 Inner part of the slide rail 4 Locking unlocking lever 5 Slide rail in pulled out position 6 Slide rail in pushed in position Figure 31 Assemb...

Page 42: ...r side to ensured that the operator doesn t have access to energized internal parts Ensure that the mains power supply socket power outlet is properly grounded and the power cable is in perfect condit...

Page 43: ...m Kontron s EMD customer section If ordered without pre installed OS before starting the KISS 2U Short V3 install the OS and the appropriate drivers for the system configuration Consider the manufactu...

Page 44: ...lter pad 3 Filter pad holder with knurled screw 4 Front access panel 5 Fan assembly Operation is permitted only with a functional fan assembly Replace a defective fan assemble only with an original fa...

Page 45: ...sten the filter pad holder by tightening the knurled screw Figure 35 pos 6 to the bolt with tapped hole Figure 34 pos 1 on the fan assembly Figure 34 Front side without filter pad Figure 35 Filter pad...

Page 46: ...fan parts The filter pad holder can be fasten to the front side of the fan assembly either before or after the fan assembly is installed in the chassis To replace the fan assembly proceed as follows 1...

Page 47: ...ust be UL recognized Do not dispose of lithium batteries in general trash collection Dispose of the battery according to the local regulations dealing with the disposal of these special materials e g...

Page 48: ...gend Power Switch 2x System Fans External PCIe Slots External Controls LEDs External Connectors 2x Drive Bays Front access PSU Power LED SSD LED 2x USB 3 1 Gen 1 2x USB 3 1 Gen 2 1x Serial port 1x DVI...

Page 49: ...xternal Controls LEDs External Connectors 2x Drive Bays Front access PSU Power LED SSD LED 2x USB 3 1 Gen 1 2x USB 3 1 Gen 2 1x Serial port 1x DVI D 2x DP 1 2 Internal Components Keyboard and Mouse 4x...

Page 50: ...torage Options Mass Storage Device 1x M 2 2280 PCIe 4 lanes Rear I O USB 4x USB 2 0 2x USB 3 1 Gen1 2x USB 3 1 Gen2 LAN 2x 1 Gb 1x i219LM 1x i210AT 10 100 1000 Mbit s ATM 12 0 vPro support Teaming sup...

Page 51: ...For more information see Chapter 3 3 Type Label 11 4 Mechanical Specification Dimension KISS 2U Short V3 with front access panel KISS 2U Short V3 without front access panel Height 88 mm 3 46 88 mm 3 4...

Page 52: ...irective LVD 2014 35 EU Electromagnetic Compatibility Electromagnetic Compatibility Directive EMC 2014 30 EU EMC Emission Class B EN 55032 CISPR 32 Electromagnetic compatibility of multimedia equipmen...

Page 53: ...ed pulse 12 2 PS 2 Mouse Connector Pin Assignment 1 fuse protected 2 low asserted pulse 12 3 USB 2 0 Port Pin Assignment 1 fuse protected Pin Signal Name Keyboard Connector 1 Data 2 NC 3 GND 4 5V 1 5...

Page 54: ...n Assignment Pin RS232 RS422 RS 485 Half Duplex RS 485 Full Duplex COM Connector 1 DCD Tx Data Tx 2 RxD Tx Data Tx 3 TxD Rx Rx 4 DTR Rx Rx 5 GND GND GND GND 6 DSR 7 RTS 8 CTS 9 RI 12 6 DVI D Connector...

Page 55: ...MX4 7 NC 8 MX4 8 NC 12 8 USB 3 0 and USB 3 1 Gen1 Gen2 Port Pin Assignment Pin Signal Name Pin Signal Name USB 3 0 3 1 Type A Connector 2 1 5V 1 5 USB3_RX 2 USB2_D 6 USB3_RX 3 USB2_D 7 GND 4 GND 8 US...

Page 56: ...r replaced within the stipulated warranty period Follow these steps before returning any product to Kontron 1 Visit the RMA Information website Kontron s RMA Information website can be found at http w...

Page 57: ...ivery address Kontron Europe GmbH RMA Support Lise Meitner Str 3 5 86156 Augsburg Germany Phone 49 0 821 4086 0 Fax 49 0 821 4086 111 Email service kontron com 6 After Kontron Europe GmbH receives the...

Page 58: ...vered to avoid damage The storage facility must meet the products environmental storage requirements as stated within this user guide Kontron recommends keeping the original packaging material for fut...

Page 59: ...o honor the warranty even during the warranty period and shall be exempted from the statutory accident liability obligations in the event of damage caused to the product due to failure to observe the...

Page 60: ...fy environmental protection requirements where possible Many of the components used are capable of being recycled Kontron follows the Waste Electrical and Electronic Equipment WEEE Directive that aims...

Page 61: ...rd Controller Style KBD Keyboard KVM Keyboard Video Mouse LAN Local Area Network LED Light Emitting Diode LVD Low Voltage Directive micro ATX Micro Advanced Technology eXtended MEI Management Engine I...

Page 62: ...oducts and tailor made solutions based on highly reliable state of the art embedded technologies Kontron provides secure and innovative applications for a variety of industries As a result customers b...

Reviews: