KBox E-420-R1K/V1K - User Guide, Rev. 1.1
// 37
To mount the KBox E-420-R1K/V1K please proceed according to the steps described:
1.
Prepare the mounting surface with sufficient screws (four screws for VESA mount) and if necessary anchors
corresponding to the mounting surface type if no VESA-compliant screw holes are available. (The recommended
screw size is M4 x 6 ~ 10 mm but it still depends on the available screw holes of the mounting surface and never
be larger than M4 if any.)
2.
Secure the base mounting bracket to the mounting surface with screws (Figure 12).
Figure 12: Securing the base mounting bracket
3.
Secure the hooked mounting bracket onto the bottom side of the KBox E-420-R1K/V1K (Figure 13) with M3 screws
(6 mm long) via the VESA 75 mounting holes. The orientation depends on applications. The below illustration
shows the case when both I/O panels are placed rightward and leftward respectively.
Figure 13: Securing the hooked mounting bracket onto the KBox E-420-R1K/V1K