KBox C-103-CFL-x - User Guide, Rev. 1.0
// 69
8.3.
DC Power Plug Terminal
The KBox C-103-CFL is connected by a Phoenix connector to a DC power source via a DC power supply wiring (only the
Phoenix power plug terminal is included).
The KBox C-103-CFL is delivered with a DC power plug terminal (3-pin Phoenix connector). For DC connection, prepare
the connecting wires using the supplied Phoenix plug terminal: PSC 1,5/ 3-F.
Figure 53: Phoenix power plug terminal
1
3-pin Phoenix plug terminal
2
Cover over the slotted pan head screws
3
Location for inserting the functional earth wire
4
Location for inserting the “24V” wire
5
Location for inserting the “0V” wire
8.3.1.
Cabling
For the pin assignment Phoenix power plug terminal refer to the subsection 4.5.1 “X101/X201 – Power Input
Connectors”.
1.
Cut the required length three isolated wires (1 mm
2
) AWG18 and strip each end 5 –7 mm.
2.
Twist the striped wire-ends and provide them with ferrules.
3.
Open the cover (Figure 53, pos. 2) to have access to the slotted pan head screws.
4.
Loosen the slotted pan head screws of the DC plug terminal far enough so that you can insert the end of the
prepared wires.
5.
Insert the wires into the corresponding clamp of the Phoenix plug terminal. Make sure that you have the right
polarity of the connection [refer to Figure 53, Figure 14 or subsection 13.1.1, “(X101) Power Input Connector “].
6.
Fasten the screws to secure the wires into the clamps of the plug terminal.
7.
Close the cover (Figure 53, pos. 2).
1
2
4
5
3