We choose the options with the + and - keys and set them with the OK key:
• C1 → Setting temperature in °F or °C
• C2 → Setting the type of control
Selection of variable hysteresis control options of 0.2 °C, 0.3 °C, 0.5 °C, 0.7 °C or PID
with a minimum time between actuations of 10, 15, 20 and 25 minutes.
• C3 → Low battery
Protection against low battery. Turns off the relay on detecting low battery: OFF
(without protection), ON (with protection).
• C4 → Selection of cooling or heating equipment
• C5 → Pump anti-blocking protection
Turns on the heating every Monday from 00:00 to 00:10.
• C6 → Thermostat firmware version
• C7 → Relay operation
We select whether the relay contact operates as NC (normally closed) or NO (nor-
mally open).
4. TERMOWEB METER
Turn off the power supply to your electrical panel. If you have several circuits, disconnect the
thermal circuit breaker where you are going to make the connection.
Connect the power cord to the TERMOWEB METER’s L and N terminals. Remember to dis-
connect the power from the thermal circuit breaker where you are going to connect the TER-
MOWEB METER.
Place the TERMOWEB METER in one of your electrical panel’s DIN rails that has space avai-
lable. (1)