Run 120V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the

wiring plate. Refer to the wiring diagram, and connect the wires as shown.

CONNECT ELECTRICAL WIRING

Install ceiling material to complete the ceiling construction. Then, cut around the fan housing.

To attach the grille assembly to the fan housing, pinch the grille springs on the sides of the grille

assembly, and position the grille into the housing with the grille springs in the appropriate slots.

Push the grille assembly towards the ceiling to secure.

INSTALL GRILLE

SERVICE PARTS

PART

PART NAME

Qty.

1
2
3
4
5
6
7
8
9

10

11
12

a

d
e
f

b
c

Housing

Screw
Screw
Screw
Screw
Screw
Screw

Blower

Motor

1
2

1

Power box

1

1
1
1
1
1
1
1
1

3
3
3
1
1
1

Grille Assembly (includes part 2)
Grille Spring

Hanger Bar 

Blower Assembly includes part 3, 4, 5, 6, b, c.

*Replacement parts are shown for illustration purposes only and are not sold seperately

WARNING: 

Before replacing, be sure to turn off power at power source.

WARRANTY

1

2

3

4
a

b

f

e

d

8

9

10

11

12

6

7

c

5

Damper / Duct Connector

Wire Panel / Harness Assembly

Blower Wheel

Wiring plate

Motor plate

UNIT

BLACK (BLK)

SWITCH BOX

SWITCH 

I

POWER SUPPLY

120V AC

GROUND (GRD)

WHITE (WHT)

FAN 

RECEPTACLE

WIRE 

PANEL

SWITCH

 I

SWITCH

 II

SWITCH 

II

BROWN (BRN)

FAN

BRN

BLK

WHT

UNIT

SWITCH BOX

WHT

GRD

GRD

LINE

   IN

BLK

S&P USA Ventilation Systems, LLC. & S&P Canada Ventilation Products, Inc. warrants to the original end user of its products that our exhaust fans will be free from defects in

materials and workmanship for a period of Six (6) years from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING

BUT NOT LIMITED TO IMPLIED WARRANTIES OF SUITABILITY FOR A PARTICULAR PURPOSE.

During this six year period, S&P will, at its option, repair returned products or parts, or provide replacement products or parts, without charge, for any product or part which is

found to be defective under normal use.

This warranty does not cover normal maintenance and service or any parts that have been subject to misuse, negligence, accident, improper maintenance or repair, faulty

installation or installation contrary to recommended installation instructions.

S&P’s obligation to repair or replace, at S&P’s option, shall be the purchaser’s sole and exclusive remedy under this warranty. No labor or materials are covered by this

warranty. S&P shall not be liable for incidental damages arising out of or in connection with product use or performance.

This warranty gives you specific legal rights. You may also have other rights which vary from state to state.

To qualify for warranty service, you must notify S&P at the address or telephone number stated below, provide the model number and part identification, and describe the

nature of any defect in product or part. You may be required to ship a defective part to S&P. There will be no charge for shipping repaired or replacement parts from S&P to

you if your address is in the United States or Canada. At the time of requesting warranty service, you must present evidence of the original purchase date.

S&P USA Ventilation Systems, LLC.

6393 Powers Avenue Jacksonville, FL 32217

P. 904-731-4711

F. 800-961-7379

www.solerpalau-usa.com

S&P Canada Ventilation Products, Inc.

6710 Maritz Drive Unit #7 Mississauga, ON L5W 0A1 - Canada

T. 416-744-1217

F. 416-744-0887

www.solerpalaucanada.com

4

Summary of Contents for PCLPD100XHP

Page 1: ...g equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities e When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden...

Page 2: ... is detected a Humidity above a user adjustable setpoint 30 80 relative humidity b rapid increases in humidity After delay timer 20 minutes returns fan to the default low speed Humidity sensor description according to HUMIDITY SENSOR OPERATION and SENSITIVITY ADJUSTMENT HUMIDITY SENSOR OPERATION The humidity sensing fan uses a sophisticated humidity sensor that responds to a rapid increases in hum...

Page 3: ...ts the inner surface of the stud Screw the mounting flange to the stud stud through the holes A and B on the same side Screw the hanger bar onto the stud through its hole Screw the hanger bar to housing with screw A The minimum installation distance between studs is 13 3 8 in 340mm Connect the round ductwork not included to the damper duct connector and run the ductwork to a roof or wall cap not i...

Page 4: ... the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF SUITABILITY FOR A PARTICULAR PURPOSE During this six year period S P will at its option repair returned products or parts or provide replacement products or parts without charge for any product or part which is found to be defective under normal use This warranty doe...

Reviews: