Slide one hanger bar into the channel on the housing and adjust as needed to fit 

between framing. Hold housing in place so that the mounting flange contacts the 

bottom of the joist, Screw the mounting flange to joist through the holes A and B. 

Screw the hanger bar onto the other side of joist through its hole. 

Screw hanger bar to housing with screw A.   

3. Mount with mounting holes

ASSEMBLY INSTRUCTIONS

4. Mount to I-joist

Slide hanger bar into the channel on the housing and adjust as needed to fit I-joist.

Hold housing in place so that the mounting flange contacts the bottom of the joist.

Screw the mounting flange to the joist through holes A and B. Screw the hanger

bar onto the joist through its hole.

Screw the hanger bar to the housing with screw A.

6. INSTALL ROUND DUCTWORK

    

5. Wall installation

5a. When the product is installed on the wall, the adaptor shall be faced upward.

5b. Slide the hanger bar into the channel on the housing. Hold the housing in place 

so that the mounting flange contacts the inner surface of the stud. Screw the 

mounting flange to the stud stud through the holes A and B on the same side. 

Screw the hanger bar onto the stud through its hole.

      Screw the hanger bar to housing with screw A.

      The minimum installation distance between studs is 13 3/8 in. (340mm)

Connect the round ductwork (not included) to the damper/duct connector, and run

the ductwork to a roof or wall cap (not included).

Using tape (not included), secure all the ductwork connections so that they are air

tight. The ducting from this fan to the outside of building has a strong effect on the

air flow, noise and energy use of the fan. Use the shortest, straightest duct routing

possible for best performance, and avoid installing the fan with smaller ducts than

recommended. Insulation around the ducts can reduce energy loss and inhibit mold

growth. Fans installed with existing ducts may not achieve their rated air flow.

Screw B

Screw A

Screw B

Screw B

Hanger

bar

Stud

Screw A

Screw B

Screw B

13 3/8 in. (340mm)

Screw A

2. Mount with mounting holes

    Hold housing in place so that the mounting flange contacts the bottom of the joist, 

    Screw the mounting flange to the joists through the holes A and B.

Screw B

Screw B

3

Summary of Contents for PCLPD100XHP

Page 1: ...g equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities e When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden...

Page 2: ... is detected a Humidity above a user adjustable setpoint 30 80 relative humidity b rapid increases in humidity After delay timer 20 minutes returns fan to the default low speed Humidity sensor description according to HUMIDITY SENSOR OPERATION and SENSITIVITY ADJUSTMENT HUMIDITY SENSOR OPERATION The humidity sensing fan uses a sophisticated humidity sensor that responds to a rapid increases in hum...

Page 3: ...ts the inner surface of the stud Screw the mounting flange to the stud stud through the holes A and B on the same side Screw the hanger bar onto the stud through its hole Screw the hanger bar to housing with screw A The minimum installation distance between studs is 13 3 8 in 340mm Connect the round ductwork not included to the damper duct connector and run the ductwork to a roof or wall cap not i...

Page 4: ... the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF SUITABILITY FOR A PARTICULAR PURPOSE During this six year period S P will at its option repair returned products or parts or provide replacement products or parts without charge for any product or part which is found to be defective under normal use This warranty doe...

Reviews: