6.     SERVICE PARTS

PART

PART NAME

Qty.

1

Grille Assembly (includes part 2)

1

2

Grille Spring

2

3

Motor Plate

1

4

Wire Panel / Harness Assembly

1

5

Motor

1

6

Blower Wheel

1

7

Hanger Bars

4

8

Housing

1

9

Wiring Plate

1

10

Damper / Duct Connector

1

11

Power Box

1

a

Screw

1

* Blower Assembly includes part 5 & 6.

Replacement Installation:

Remove the screw on motor plate 

(part 3)

, then take 

out the motor plate 

(part 3)

 from the housing 

(part 8) 

by pushing down the rib in the plate while pulling out 

on the side of the housing. Replace the broken parts.

WARNING

Ensure  that  the  fan  is  switched  off  from  the  supply 

mains before replacing.

6.     Install Grille

Install  ceiling  material  to  complete  the  ceiling 

construction  and  cut  around  the  fan  housing. 

To attach the grille assembly to the fan housing, 

pinch the grille springs on the sides of the grille 

assembly and position the grille into the housing 

with the grille springs in the appropriate slots. 

Push the grille assembly towards the ceiling to 

secure. 

Summary of Contents for PCD80XH

Page 1: ... and operation of fans manufactured by S P USA These instructions are intended to supplement good general practices and are not intended to cover detailed instruction procedures because of the wide variety and types of fans manufactured by S P USA 6393 Powers Ave Jacksonville FL 32217 P 800 961 7370 F 800 961 7379 Installation Operation and Maintenance Manual READ AND SAVE THESE INSTRUCTIONS The p...

Page 2: ......

Page 3: ...ot use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in ceilings up to a 12 12 pitch 45 degree angle Duct connector must point upwards 3 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 4 Please read specification label on product for further information and requirements ...

Page 4: ...ub area or is being used for dampness control the H may need to be increased toward maximum If the control is responding too often to changing environmental conditions movement toward less H may be required To adjust the H 1 Disconnect power at service entrance 2 Through the grille locate the slot marked H 3 Carefully rotate the H adjustment toward or 4 Turn on power and check operation by turning...

Page 5: ...d the hanger bars to the joist Use screws to secure the hanger bars to the ceiling joists Select a proper hole and secure the hanger bars together using flange screws 3 Attach Damper Duct Connector Snap the damper duct connector onto the fan housing The connector must be flush with the top of the housing and the damper flap should fall closed 4 Install Round Ductwork Connect the round ductwork not...

Page 6: ...ate part 3 from the housing part 8 by pushing down the rib in the plate while pulling out on the side of the housing Replace the broken parts WARNING Ensure that the fan is switched off from the supply mains before replacing 6 Install Grille Install ceiling material to complete the ceiling construction and cut around the fan housing To attach the grille assembly to the fan housing pinch the grille...

Page 7: ...the fault THE FOLLOWING WARRANTIES DO NO APPLY Damages from shipping either concealed or visible Claim must be filed with the carrier Damages resulting from improper wiring or installation Damages caused by acts of nature or resulting from improper consumer procedures such as Improper Maintenance Misuse Negligence Alteration Abuse Abnormal Use or Accident or Incorrect Electrical Voltage and Curren...

Page 8: ......

Reviews: