S&P ALTAIR 160 H Manual Download Page 15

15

2.9. PUTTING OUT OF SERVICE AND RECYCLING

EEC legislation and our consideration of future generations mean that we should always recycle materials 
where possible; please do not forget to deposit all packaging in the appropriate recycling bins. If your device 
is also labeled with this symbol, please take it to the nearest Waste Management Plant at the end of its ser-
vicable life.

2.10. ERP DATA

Ecodesign

Commission regulation (EU) N°1253/2014 of July 2014

Information requirements (Annex V)

ALTAIR 120 H

ALTAIR 160 H

a

Trade mark

   S&P

S&P

b

Identifi er

5153811000

5153182800

c

SEC average climate (kWh/(m².an))

-38,0

-37,8

SEC class

A

A

SEC cold climate (kWh/(m².an))

-75,1

-73,9

SEC warm climate (kWh/(m².an))

-14,2

-14,6

d

Typology

RVU bidirectional

RVU bidirectional

e

Type of drive

Variable speed drive

Variable speed drive

f

Type of HRC

Recuperative

Recuperative

g

Thermal effi ciency (%)

83

79

h

Maximum fl ow rate (m³/h)

120

158

i

Electrical power input at maximum fl ow rate (W)

55,0

54

j

Sound power level (LWA)

47

48

k

Reference fl ow rate (m³/s)

0,023

0,031

l

Reference pressure difference (Pa)

50,0

96

m

SPI (W/m³/h)

0,262

0,222

n

Control factor

0,85

0,85

Control typology

Central demand

Central demand

o

Maximum internal leakage for BVU (%)

2,9

1,3

Maximum external leakage for BVU and UVU (%)

2,9

3,0

p

Mixing rate for BVU without duct connection (%)

not applicable

not applicable

q

Position of visual fi lter warning

Remote control

Remote control

description of visual fi lter warning

Pilot light

Pilot light

r

Instructions to install supply grilles

not applicable

not applicable

Instructions to install exhaust grilles

not applicable

not applicable

s

Internet address

www.solerpalau.com

www.solerpalau.com

t

Airfl ow sensitivity to pressure variation

not applicable

not applicable

u

Indoor/outdoor air tighness (m³/h)

not applicable

not applicable

v

Annual electricity consumption - Average climat (kWh/a)

282

246

Annual electricity consumption - Warm climat (kWh/a)

237

201

Annual electricity consumption - Cold climat (kWh/a)

819

783

w

Annual heating saved - Average climat (kWh/a)

4440

4332

Annual heating saved - Warm climat (kWh/a)

2010

1959

Annual heating saved - Cold climat (kWh/a)

8690

8474

Summary of Contents for ALTAIR 160 H

Page 1: ...ALTAIR 120 H ALTAIR 160 H False ceiling mounting EN...

Page 2: ...or air ODA 4 Extract air ETA 5 Supply air SUP 6 G4 lter extract air 7 G4 lter outdoor air 8 Supply air fan 9 Exhaust air fan 10 Counter ow heat exchanger 11 Humidity sensor 12 Condensation water conne...

Page 3: ...e chemical agents Means for disconnection must be incorporated in the xed wiring according with the wiring rules An external disconnecting device which will function as the designated disconnect devic...

Page 4: ...ce the parts or the unit whose operation is recognized defective by our departments except for all damages and interests or penalties such as operating losses commercial prejudice or other immaterial...

Page 5: ...densation Supply air SUP To avoid thermal losses and optimize the per formance of the installation it is recommended to use insulated duct Extract air ETA To avoid thermal losses and optimize perfor m...

Page 6: ...D 94 mm 123 mm E 22 mm 22 mm F 660 mm 729 mm G 850 mm 970 mm H 30 mm 32 mm I 178 mm 211 mm J 91 mm 106 mm K 208 mm 231 mm A 104 80 26 52 60 17 blue DO D1 12V COM red green white L N L N 230V 50 60Hz...

Page 7: ...lly insulated type GP ISO 125 25 6M ECOSOFT 5209346000 lateral view ALTAIR 120 H X 30 mm ALTAIR 160 H X 20 mm X Z Y Dim ALTAIR 120 H ALTAIR 160 H Y 874 mm 994 mm Z 516 mm 516 mm The drain pipe should...

Page 8: ...d Potentiometer position 0 1 2 3 4 5 6 7 8 9 A B C D E F ALTAIR 120 H Assigned value m3 h 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 120 ALTAIR 160 H Assigned value m3 h 40 48 56 64 72 80 88 96 1...

Page 9: ...change Of course after the installation the extract air is dusty and not representative During the second lter check if you notice that the lters are clean you can increase the time if you notice the...

Page 10: ...to adjust the velocity in dependence of the relative humidity in the extract air The upper limit of the relative humidity can be adjusted with the potentiometer as shown below factory setting positio...

Page 11: ...ou to con nect the ALTAIR unit with the S P IoT Platform CONNEC TAIR To connect the SPCM 1 module to the ALTAIR you must rst disconnect the control 14 and then connect the SPCM 1 with the cable suppli...

Page 12: ...right fan symbol increase speed ORZ VSHHG PHGLXP VSHHG KLJK VSHHG Automatic mode Pressing the button A there can be activated the automatic mode In the automatic mode works the unit proportio nal in...

Page 13: ...chan ging the lter put back the plastic taps Everytime when lters are replaced the lter main tenance period has to be reseted pressing the but ton A during 5 seconds 2 6 STANDBY FUNCTION Push and hold...

Page 14: ...r 8 red blinks normal operation 7 ETA sensor error extract air 9 red blinks normal operation 8 EHA sensor error exhaust air 10 red blinks normal operation 9 Filter alarm Red continous after 60 days th...

Page 15: ...nd power level LWA 47 48 k Reference ow rate m s 0 023 0 031 l Reference pressure difference Pa 50 0 96 m SPI W m h 0 262 0 222 n Control factor 0 85 0 85 Control typology Central demand Central deman...

Page 16: ...S P SISTEMAS DE VENTILACI N S L U C Llevant 4 Pol gono Industrial Llevant 08150 Parets del Vall s Barcelona Espa a Tel 34 93 571 93 00 www solerpalau com Ref 9023110800 03...

Reviews: