DoC Report 
2006137 
04/27/07 

 

5.3  RADIATED EMISSIONS TEST DATA 

 

Temperature: 48°F 

Humidity: 36% 

Emission 

Frequency 

(MHz) 

Test 

Detector 

Antenna 

Polarity 

(H/V) 

Turntable 

Azimuth 

(deg) 

Antenna

Height 

(m) 

Analyzer

Reading 

(dBuV) 

Site 

Correction

Factor 

(dB/m) 

Emission 

Level 

(dBuV/m) 

 

Limit 

(dBuV/m) 

 

Margin

(dB) 

Pass/

Fail 

 

50.000 Qp  H  200  3.0  38.4 -22.2 16.2 30.0 

-13.8 

Pass 

 

73.800 Qp  V  100  1.0  41.6 -23.5  18.1  30.0 

-11.9 

Pass 

 

144.000 Qp 

1.0  40.1  -18.5  21.6  30.0 -8.4 

Pass 

 

191.992 Qp 

80 

1.0  42.2  -19.4  22.8  30.0 -7.2 

Pass 

 

200.000 Qp 

190  1.0  35.3  -19.0  16.3  30.0 -13.7 

Pass 

 

225.000 Qp 

290  1.0  32.7  -18.5  14.2  30.0 -15.8 

Pass 

 

250.000 Qp 

160  4.0  44.2  -15.5  28.7  37.0 -8.3 

Pass 

 

369.340 Qp 

190  1.5  42.8  -12.1  30.7  37.0 -6.3 

Pass 

 

406.340 Qp 

270  1.0  32.9  -10.5  22.4  37.0 -14.6 

Pass 

 

463.850 

Qp H  75 2.5 

38.8 -9.5 29.3 37.0 

-7.7 

Pass 

 

485.970 Qp 

190  1.0  29.4  -8.9  20.5  37.0 -16.5 

Pass 

 

631.945 Qp 

45 

1.0  30.8  -6.2  24.6  37.0 -12.4 

Pass 

 

700.000 Qp 

1.0  30.4  -5.8  24.6  37.0 -12.4 

Pass 

 

 
Note: 
The EUT was scanned from 30 MHz to 15,000 MHz.  All emissions other than those listed in the tables above were found to 
have amplitudes attenuated by more than 20dB below the FCC limit. 

 
Result:  Pass 

 
 
Test Personnel: 

Jon Wilson 

 

April 10, 2007 

EMC Test Engineer 

Signature 

Date Of Test 

 

 

 

 
 

Summary of Contents for CompactFlash 5000

Page 1: ...rporation 7 Atir Yeda Street Kfar Saba Israel Phone 972 9 7644908 Device Under Test SanDisk SSD SATA 5000 2 5 Document Number 2007160 Reference Number QRTL07 033 This report may not be reproduced exce...

Page 2: ...g FCC Class B Compliance Standard s to which device was tested STANDARDS SPECIFIC TESTS APPLICABILITY Tested Not Tested CFR47 Parts 15 109 and 15 107 Radiated and Conducted Emissions Test Engineer Jon...

Page 3: ...IGURATION OF TESTED SYSTEM 7 3 PRODUCT LABELLING INFORMATION TO THE USER 8 3 1 DOC LABEL ON DEVICE 8 3 2 DOC STATEMENT IN USER S MANUAL 8 3 3 LOCATION OF LABEL ON EUT 8 4 CONDUCTED EMISSIONS 9 4 1 SIT...

Page 4: ...te 1400 Herndon Va 20170 Complete description and site attenuation measurement data has been placed on file with the Federal Communications Commission The power line conducted emission measurements we...

Page 5: ...sis o Operating shock 1 500G 0 5msec half sine o Operating vibration 2 17G 7 500 Hz o Operating temperature 0 C to 70 C o Non operating temperature and storage 55 C to 95 C o Operating temperature 0 C...

Page 6: ...on RTL Bar Code Equipment Arrival Date Laptop PC Dell Latitude D620 PP18L N A DoC Unshielded Power N A 4 10 2007 Laptop AC Adapter Dell LA65NS0 00 CN 0DF263 71615682 2ED4 N A Unshielded 017737 4 10 20...

Page 7: ...1400 Herndon VA 20170 http www rheintech com SanDisk Corporation Page 7 of 17 DoC Report 2006137 04 27 07 2 5 CONFIGURATION OF TESTED SYSTEM Laptop PC with SanDisk SSD SATA 5000 USB Termination Monito...

Page 8: ...pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate...

Page 9: ...ne and electrically connected to the peripheral LISN powers the EUT host peripherals The spectrum analyzer was connected to the A C line through an isolation transformer The 50 ohm output of the EUT L...

Page 10: ...9 56 0 19 1 46 0 9 1 Pass 15 070 Pk 25 2 2 3 27 5 60 0 32 5 50 0 22 5 Pass 17 640 Pk 28 2 2 5 30 7 60 0 29 3 50 0 19 3 Pass 25 100 Pk 29 4 2 7 32 1 60 0 27 9 50 0 17 9 Pass Phase Conductor Temperatur...

Page 11: ...360 Herndon Parkway Suite 1400 Herndon VA 20170 http www rheintech com SanDisk Corporation Page 11 of 17 DoC Report 2006137 04 27 07 4 3 CONDUCTED TEST PHOTOGRAPHS...

Page 12: ...ency the EUT was rotated 360 and the antenna was raised and lowered from 1 to 4 meters in order to determine the emission s maximum level Measurements were taken using both horizontal and vertical ant...

Page 13: ...orrection Factor SCF used in the above equation is determined empirically and is expressed in the following equation SCF dB m PG dB AF dB m CL dB SCF Site Correction Factor PG Pre amplifier Gain AF An...

Page 14: ...1 0 42 2 19 4 22 8 30 0 7 2 Pass 200 000 Qp V 190 1 0 35 3 19 0 16 3 30 0 13 7 Pass 225 000 Qp V 290 1 0 32 7 18 5 14 2 30 0 15 8 Pass 250 000 Qp H 160 4 0 44 2 15 5 28 7 37 0 8 3 Pass 369 340 Qp H 19...

Page 15: ...360 Herndon Parkway Suite 1400 Herndon VA 20170 http www rheintech com SanDisk Corporation Page 15 of 17 DoC Report 2006137 04 27 07 5 4 RADIATED TEST PHOTOGRAPHS...

Page 16: ...Solar 8130 947306 900729 N A 16A LISN AFJ International LS16 110VAC 16010020080 901083 4 4 2008 16A LISN AFJ International LS16 110VAC 16010020081 901082 1 6 2008 Current Probe Telecom conducted Fisc...

Page 17: ...g the measurement procedure and test equipment that was used contained in the test report iv A description of the equipment under test EUT and support equipment connected to or installed within the EU...

Reviews: