Overtaxed compressor:
Compressor too small
Restrict time used
Nozzle size too large
Use smaller size
Too many leaks in plumbing
Seal and tighten plumbing
Holes in abrasive hose
Replace hose
Air filter on compressor plugged
Clean
Lack of air pressure:
Compressor too small
Use smaller nozzle
Supply valves not on full position
Open valves
Nozzle size too large
Use smaller size
Leaks in plumbing
Seal and tighten plumbing
Holes in abrasive hose
Replace hose
Air filter on compressor plugged
Clean filter
Urethane gasket worn or dirty
Clean or replace gasket
Lack of abrasive flow:
Blaster tank empty
Fill tank
Moisture in media
Dry media
Not enough air pressure
Check system
Abrasive hose kinked
Straighten hose
Debris in media
Clean or screen media