water temperature is lower than the preset one, the filtration pump and heater will work till the
water temperature reaching the preset one. Then, the filtration pump will return to work for 1
hour and stop for 3 hours repeatedly. When quit from the automatic mode, the filtration pump
won’t controlled by temperature.
Each time when turn on the spa, the system will go into the mode set last time. Long press
or
key (the indicator will show
GREEN
) to switch between automatic mode and manual
mode.
When enters into automatic mode:
A: The preset temperature is lower than the actual water temperature: only the filtration pump
works while the heater does not work.
B: The preset temperature is higher than the actual water temperature: when under the state of
“stop”, if the water temperature has not reached the preset one, the filtration pump and heater
will continue to work until the water temperature reaches the preset one. The Ozone will
automatically work together with the filtration pump and heater in automatic mode.
Control box environmental overheat protection function: When the inside temperature of the
control box exceed an appropriate temperature, the control system will be shut down
automatically. When the temperature returns to appropriate temperature, the indicator light of
ON/OFF key flashes and the control panel recovers to standy status. Pressing ON/OFF, the
control system can be used as normal.
Water overheat protection function: When the water in spa reaches to 43
℃
,
some parts stop
working and “OH” shows on the screen. The above parts includes air blower, heater and all
massage pumps. When the temperature down to 40
, “OH” disappears. The functions can be
℃
used as normal by controling the control panel.
Screen protection function: The backlight of screen will be turned off after 1 minute switching on
the control panel. The indicator lights of function keys on the panel stay lit.
Time controls functions: The massage pump and air blower will be shut down automatically after
running 1 hour. All indicator lights of functional keys lit. The heater and circulation pump are
controled by temperature.
Automatic cleaning function
:
Keep the spa power on. The system will do the clean
automatically every 12 hours from shutting off the spa by pressing the ON/OFF key. All the
equipments will go into working for one minute in turn and stop working automatically. Their
order is air blower and circulation pump (working in the same time), PUMP1, PUMP2 and
PUMP3, four cycles in total. After one equipment stopping, the next one will go into working
automatically, until the last (fourth) cycle.
III.SInstructionsSaboutStheSCombinationSLockSofSSPA’sSCover
The preset number to open the combination lock at 0-0.
You can reset the combination to your own number as follows: Open your combination lock. Use
your ball point pen or other small strike to press in the reset button. Rotate the dial to the number that
you want to set while keeping the reset button depressed. Release the reset button and reset the other
side of the lock by the same way.