temperature sensor is disconnected, check the wiring of temperature sensor to see whether it is
disconnected. When the panel shows E1 which means the temperature sensor is short-circuited,
replace the temperature sensor with a new one. The heating system can not be activated under the
above two situations.
Water-lackingSprotectionSsystemSforScirculationSpumpSandSheater:S
In daily usage, the blockage of
filtration medium (cartridge filter or filter bag) will occur. The severe blockage will lead to the
intermittent lack of water for the filtration pump. When lack of water, the filtration pump and heater
will stop working automatically. At this moment, the symbol of filtration pump
S
on control panel
will flash unceasingly, which reminds the user that it is time to clean or replace the filtration medium.
After cleaning or replacing the filtration medium, press
S
several times so that it can evacuate the
air inside the pipe until the filtration pump work normally.
Anti-freezing S system:
After power on to enter standby status (the indicator light on
key
flashes), the anti-freezing system will be activated instantly. The circulation pump and heating system
will automatically stop at the default temperature of above 10
. When the water temperature in the
℃
spa drops below 9
, the circulation pump, heater and air blower will work automatically, Pump1 will
℃
automatically start to work in about 85 seconds; and it will stop after working about 85 seconds; then
Pump 2 (if equipped) will start to work for about 85 seconds and stop; finally comes for Pump 3 (if
equipped) working for about 85 seconds then stops. Pump1, Pump2 and Pump3 will continuously
cycle among them. When the detected water temperature reaches 10
, all the pumps and heater will
℃
stop working. When this system is running, the screen background light is on. When the water
temperature reaches 10
, the screen returns to the standby status.
℃
Remark:
When enjoy the massage functions, in order to ensure the cleanness of water in the spa,
please switch the spa into manual mode.
AutomaticSworkingSmode:S
(The factory-setting for the spa is automatic mode)
Long press
key for 3 seconds to enter automatic mode (the indicator light on
key will
show
GREEN
). The circulation pump will start to run automatically for 60 minutes and then stops for
180 minutes. It will repeat the cycle continuously. During the running time,
key will show
GREEN
, and the panel will display “ON”, detected water temperature and the symbol of ozone
alternately. The heater will go to work instantly if the water temperature is 2
lower than the preset
℃
temperature. And its symbol will be displayed on the panel. During the stop running time,
key
will show
GREEN
, and the panel will display “OFF” and detected water temperature alternately.
When the water temperature is 2
lower than the preset temperature, the circulation pump, ozone
℃
generator and heater will go to work instantly until it reaches the preset temperature. The keys
are non-functional keys, they act as indicating keys.
REMARK:
If the spa is in automatic working mode, please don’t turn off the spa when you don’t use it and
make sure to keep the spa always “
on”
.
When enters into automatic mode, the filtration pump will be controlled by temperature. If the
4