O

perating

 i

nstructiOns

S&G

 Model 2740B

  

Electromechanical Safe Lock

l

ock

 o

pen

 l

atch

 — 444 D

evice

 r

equIred

If the lock’s low battery warning signal is ignored for approximately one hundred consecutive openings, the 2740B will go into 

Lock Open Latch

 

condition. It cannot be locked. To reset the Lock Open Latch, attach a fresh 9-volt battery to a Sargent & Greenleaf 

444 Device

 (S&G part 

number 2740-444), then plug the device’s connector into the lock’s change key port on the outside of the cover. As soon as it’s plugged into the 
cover, the lock motor will run briefly to reset the Lock Open Latch condition. Unplug the 

444 Device

, and turn the dial to extend the lock bolt. 

REMOVE THE LOCK COVER AND REPLACE BOTH LOCK BATTERIES IMMEDIATELY. DO NOT ATTEMPT TO OPERATE THE LOCK WITH  
THE 

444 Device

 

LEFT PLUGGED INTO THE COVER

.

c

hangIng

 

the

 l

ock

 b

atterIes

1.   With the container (safe) door or drawer open, extend the locking bolts. This is referred to as locking the container open.

2.   If the 2740B lock bolt is not extended already, turn the dial left (counterclockwise) to extend it.

3.   Remove the two lock cover screws and carefully lift the cover off of the lock body. Do not let any metal (conductive) tools touch anything on 

the underside of the cover.

4.  Remove the CR123A camera-type battery from the cover first.

5.   You can use the back end of a 2740 change key to help push the CR2450 coin cell partially out of its holder. 

Then you will be able to grasp it with your fingers and pull it completely out of the holder. Dispose of both  
batteries responsibly.

6.   Wait one minute after removing the old batteries before installing the fresh, new ones.

7.   Slide a new coin cell battery into its housing first, positive side up. Within one minute, install the camera-type battery into its receptacle. 

Never force batteries into place. If batteries are installed backwards (incorrect polarity), no electrical damage will occur, but the lock will not 
function properly.

8.   When the backup battery (coin cell) and then the main battery (camera-type) are installed, you will hear a beep.  If you have not 

waited one minute between removal of the old batteries and installation of the new ones, the beep may not occur. If you do not 
hear the beep, remove both batteries and repeat the installation process, inserting the coin cell battery first.

S&G 

444 Device

S&G 

444 Device 

with attached 9-volt battery

Connecting the 

444 Device 

to 

the lock change key port

Summary of Contents for 2740B

Page 1: ...period of ten minutes Entering a correct combination before reaching the tenth incorrect entry in a row resets the wrong combination counter It doesn t make any difference how much time intervenes bet...

Page 2: ...Combination Changing Notes page 4 Changing the Combination with the Change Key page 4 Lock Setup and Maintenance Functions Dial Calibration page 5 Battery Condition Check page 5 Battery Issues Low Bat...

Page 3: ...ion left counterclockwise To Open the Lock in Dual User Mode Dual user mode simply means that two different combinations are needed to open the lock Typically each combination is held by a different p...

Page 4: ...stop precisely on the first number of the OLD combination 5 Turn the dial right clockwise stopping when the second OLD combination number comes to the index 6 Turn the dial left stopping when the thi...

Page 5: ...al open the lock even though you are being very careful and staying focused while dialing It takes less than a minute to calibrate the dial to zero The number of revolutions you must turn before heari...

Page 6: ...ock cover screws and carefully lift the cover off of the lock body Do not let any metal conductive tools touch anything on the underside of the cover 4 Remove the CR123A camera type battery from the c...

Page 7: ...then re install them beginning with step 6 If you still do not hear the battery confirmation beep at the end of the ten second battery check or if you hear the low battery signal replace both batterie...

Page 8: ...eft counterclockwise at least two complete revolutions Now stop when the first number of the NEW user 1 combination comes to the index 9 Turn the dial right clockwise until the second number of the NE...

Page 9: ...ise stopping when the second number of the 2nd existing dual user combination comes to the opening index 10 Turn the dial left stopping when the third number of the 2nd dual user combination comes to...

Page 10: ...ial left until the third number of the RECOVERY combination comes to the index Then turn the dial right until you hear three quick beeps from the lock 7 Turn the dial left counterclockwise at least tw...

Page 11: ...code is entered for the first time while changing from single to dual user mode 3 beeps sounded between most steps of a programming sequence the exception is the preceding table entry 4 beeps sounded...

Page 12: ...RPOSE EXCEPT AS EXPRESSLY PROVIDED HEREIN Seller s entire liability and Buyer s exclusive remedy in the event that the goods do not conform to the foregoing warranty shall be Seller s repair or replac...

Reviews: