background image

6

06/2005

SET-UP AND CODE DESCRIPTION (CONTINUED)

 

        MIS Data – Sales Mode

If selection button two is pressed at the “

” prompt, the display will show the non-resettable 

historical amount of units sold by the machine. If selection button one is pressed, the display 
will show “

” (selection one) and the units sold for selection button one. Continue pressing 

selection button one to scroll through all of the selections. To exit the setting, press selection 

button three.

 

        Cost Setting Mode 

The  purpose  of  this  mode  is  to  enable  the  controller  to  set  the  vend  price  for  each  of  the 
selections. If selection button two is pressed at the “

” prompt, the display will indicate “

”. 

Pressing selection button one will scroll through all of the selections or “

” to have all the vend 

prices set at the same price. Pressing selection button two will enter into the displayed selection 

button. Pressing selection button one will change the displayed vend price. Pressing selection 

button two again will save the price and selection button three will exit the mode.

 

        Discount Counter

 

(Only shows when discounts are used) 

The discount counter allows you to access the sales and cash data for vends that have been 
discounted.  Press selection button #2 when the display reads 

 The display will change to 

read 

.  Press selection button #2 when the display reads 

.  The display will change 

to read 

 and XXXX.XX, where XXXX.XX is the value of all discounts towards paid sales. 

This total is non-resettable and begins when the discount feature is enabled.  Pressing selection 

button #1 will scroll through all of the selection buttons and display the value of the discounts 

toward product sales. The amounts for the individual selections can be reset using the rules in 
the 

 mode.  To exit this mode, press selection button #3.  The display will return to 

  

To advance to the sales information, press selection button #1.  The display 

 

will change 

to 

.  Press selection button #2 to access this information. The total number of discounted 

sales will be displayed. This total is non-resettable and begins when the discount feature is 

enabled.  Pressing selection button #1 will scroll through all of the selection buttons and display 

each selection’s number of discounted sales. The amounts for the individual selections can be 
reset using the rules in the 

 mode.

 

        Free Counter

 

(Only show if free vends during closed-door sales mode have been made) 

The free counter allows you to access the sales and cash data (loss) for vends that have been 
free.  Press selection button #2 when the display reads 

.  The display will change to read 

XXXX.XX, where XXXX.XX is the value of all lost money based on the price value setting. This 

total is non-resettable and begins when the free vend override feature is enabled.  Pressing 
selection button #1 will change to the second screen. The display will change to read 

 

XXX.XX. It will display the total number of free vends that have occurred. This total is non-

resettable and begins when the free vend override feature is enabled.  Press selection button 

#3 to exit the mode.

Summary of Contents for V21 Series

Page 1: ...1 06 2005 12 1 PROGRAMMING SECTION...

Page 2: ...rvice mode as indicated in the following steps below The main service modes are indicated in white text and the sub modes are indicated in black text Example Time Date Setting Mode Year Setting Month...

Page 3: ...settable MIS data will be displayed if no errors exist XXX will ash for approximately 30 seconds indicating the total number of units the machine has sold After 30 seconds XX XX will begin to scroll i...

Page 4: ...f selection button two is pressed a pay out of the displayed value will be made Coins will continue to pay out as long as that selection button is held down EXAMPLE If selection button two is pressed...

Page 5: ...roller into the Relay test mode which allows the user to test the lights compressor evaporator fans or the heater Upon entry into the rely test mode the display will read for the compressor test To sc...

Page 6: ...paid sales This total is non resettable and begins when the discount feature is enabled Pressing selection button 1 will scroll through all of the selection buttons and display the value of the discou...

Page 7: ...cription Meaning Force Select Force select enabled y or disabled n Bill Escrow Bill Escrow enabled y or disabled n Error Sold Out Indicator Error Sold Out indicator enabled y or disabled n Single Pric...

Page 8: ...ered If the column number is steady it is not assigned to the selection button To exit this mode press selection button three FIGURE 3 SEL ST10 STS9 STS8 STS7 STS6 STS5 STS4 STS3 STS2 STS1 COL COL COL...

Page 9: ...n two is pressed at the prompt the controller will enter the Language Mode by displaying the currently assigned language The available languages are English French German Italian Portuguese and Spanis...

Page 10: ...me Hour associated with 2nd start time 2nd End Time Time lights turn back on Days associated with 2nd end time Hour associated with 2nd end time Refrigeration Mode Ifselectionbuttontwoispressedatthe p...

Page 11: ...l turn on off with the activation of the compressor 1 Fan Mode 1 the evaporator fan will turn off 5 minutes after the compressor fan is turned off The second submode refers to the Periodic Defrost mod...

Page 12: ...toggle between the following modes REFRIGERATION CONTROL SETTINGS Refrigeration control enabled 1 disabled 0 Start Time Time temperature rises 18 F 10 C Days associated with start time Hour associate...

Page 13: ...ime when the discount will occur If selection button two is pressed at the prompt the controller will enter the Discount Setting Mode Upon entry into this program the display will show If selection bu...

Page 14: ...button two is pressed at the prompt the controller will enter the Free Vend Enable Option Upon entry into this program the display will show the current setting Press selection button two Pressing se...

Page 15: ...ver Ride Option Upon entry into this program the display will show the current setting for enable and for disable Pressing selection button one will toggle between y for enabled and n for disable Pres...

Page 16: ...14 1 2 3 4 15 16 5 6 17 18 7 8 19 20 9 10 YEL VIO GRY PNK WHT BRN ORN BLU J2 5 6 7 8 1 2 3 4 RED ORN VIO BLK 2 4 6 8 J6 1 3 5 16 7 9 M3 GRY M4 PNK M5 RED M6 BRN M7 ORN M1 YEL M2 VIO M8 TAN 10 11 12 1...

Page 17: ...FRIG HEATER OPTION W A R M CABINET WARM CABINET COLD CABINET WARM CABINET COLD VS2 C O L D TRANSFORMER PRIMARY 24 VAC WHT BLK NO 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 1 2 POWER DIST BOX LIGHT RELAY...

Page 18: ...18 06 2005 NOTES 1 If the outer door is left open for over an hour the lights and compressor will become active In order to over ride this option press the door switch one time...

Reviews: