       Error Display Mode

If selection button two is pressed at the “

” prompt, the controller will enter the Error 

Display Mode.  If no errors have occurred, the display will show “

”. If an error has been 

detected since the last error reset, the display will show the first error summary code that 

has occurred. If selection button three is pressed while displaying any summary code, the 
controller will return to the “

” prompt. 

Note:

 See the Trouble Shooting section for errors and how to clear them.

EXAMPLE:

  

 would indicate a column jam error in column 1.

                 

                  Coin Pay Out/Tube Fill Mode

If selection button two is pressed at the “

” prompt, the controller will enter the Coin 

Pay Out Mode. Pressing selection one will scroll through the denominations and pressing 

selection  button  two  will  start  the  denomination  flashing.  The  display  will  indicate  the 

denomination along with the number of that coin stored in the coin mechanism. If selection 

button two is pressed, a pay out of the displayed value will be made.  Coins will continue to 

pay out as long as that selection button is held down.

EXAMPLE

: If selection button two is pressed while 5 cents is displayed it will pay out a 

nickel.

  
When the controller enters the “

” mode, the operator is allowed to deposit any coin into 

the coin changer’s acceptor when that coin’s tube is not full.  The tube inventory level will 

be displayed after each coin is accepted.

 

       Test Mode

If selection button two is pressed at the “

” prompt, the controller will enter the Test 

Mode where you are able to test the motors, the display, the compressor, the lights, the 

evaporator fans and the heater.

 

       Vend Testing

Pressing selection button two at the test mode will enter the controller into the vend test 

mode. Upon entry into the vend test mode the display will show the first summary test,       

 (column 1). Pressing selection button one will scroll through the column selections. 

Pressing selection button two will test vend the displayed column. In order to exit the setting, 

press selection button three.

SET-UP AND CODE DESCRIPTION

Summary of Contents for V21 Series

Page 1: ...1 06 2005 12 1 PROGRAMMING SECTION...

Page 2: ...rvice mode as indicated in the following steps below The main service modes are indicated in white text and the sub modes are indicated in black text Example Time Date Setting Mode Year Setting Month...

Page 3: ...settable MIS data will be displayed if no errors exist XXX will ash for approximately 30 seconds indicating the total number of units the machine has sold After 30 seconds XX XX will begin to scroll i...

Page 4: ...f selection button two is pressed a pay out of the displayed value will be made Coins will continue to pay out as long as that selection button is held down EXAMPLE If selection button two is pressed...

Page 5: ...roller into the Relay test mode which allows the user to test the lights compressor evaporator fans or the heater Upon entry into the rely test mode the display will read for the compressor test To sc...

Page 6: ...paid sales This total is non resettable and begins when the discount feature is enabled Pressing selection button 1 will scroll through all of the selection buttons and display the value of the discou...

Page 7: ...cription Meaning Force Select Force select enabled y or disabled n Bill Escrow Bill Escrow enabled y or disabled n Error Sold Out Indicator Error Sold Out indicator enabled y or disabled n Single Pric...

Page 8: ...ered If the column number is steady it is not assigned to the selection button To exit this mode press selection button three FIGURE 3 SEL ST10 STS9 STS8 STS7 STS6 STS5 STS4 STS3 STS2 STS1 COL COL COL...

Page 9: ...n two is pressed at the prompt the controller will enter the Language Mode by displaying the currently assigned language The available languages are English French German Italian Portuguese and Spanis...

Page 10: ...me Hour associated with 2nd start time 2nd End Time Time lights turn back on Days associated with 2nd end time Hour associated with 2nd end time Refrigeration Mode Ifselectionbuttontwoispressedatthe p...

Page 11: ...l turn on off with the activation of the compressor 1 Fan Mode 1 the evaporator fan will turn off 5 minutes after the compressor fan is turned off The second submode refers to the Periodic Defrost mod...

Page 12: ...toggle between the following modes REFRIGERATION CONTROL SETTINGS Refrigeration control enabled 1 disabled 0 Start Time Time temperature rises 18 F 10 C Days associated with start time Hour associate...

Page 13: ...ime when the discount will occur If selection button two is pressed at the prompt the controller will enter the Discount Setting Mode Upon entry into this program the display will show If selection bu...

Page 14: ...button two is pressed at the prompt the controller will enter the Free Vend Enable Option Upon entry into this program the display will show the current setting Press selection button two Pressing se...

Page 15: ...ver Ride Option Upon entry into this program the display will show the current setting for enable and for disable Pressing selection button one will toggle between y for enabled and n for disable Pres...

Page 16: ...14 1 2 3 4 15 16 5 6 17 18 7 8 19 20 9 10 YEL VIO GRY PNK WHT BRN ORN BLU J2 5 6 7 8 1 2 3 4 RED ORN VIO BLK 2 4 6 8 J6 1 3 5 16 7 9 M3 GRY M4 PNK M5 RED M6 BRN M7 ORN M1 YEL M2 VIO M8 TAN 10 11 12 1...

Page 17: ...FRIG HEATER OPTION W A R M CABINET WARM CABINET COLD CABINET WARM CABINET COLD VS2 C O L D TRANSFORMER PRIMARY 24 VAC WHT BLK NO 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 1 2 POWER DIST BOX LIGHT RELAY...

Page 18: ...18 06 2005 NOTES 1 If the outer door is left open for over an hour the lights and compressor will become active In order to over ride this option press the door switch one time...

Reviews: