S&C TripSaver II Quick Start Manual Download Page 4

4    S&C Instruction Sheet 461-503

Safety Precautions

 WARNING

DO NOT disassemble a TripSaver II recloser . The control module inside the TripSaver II recloser housing is only 
intended for use inside the TripSaver II recloser and has not been approved for any other use . There are no customer-
serviceable parts inside the recloser, and disassembling the recloser voids the warranty . If you do disassemble a 
TripSaver II recloser, NEVER power it with the power module included with the Service Center Configuration Kit 
when the inside of the recloser is exposed . Unsafe high voltage can be present on the connectors on the outside of 
the internal control box assembly, resulting in serious injury or death .

 WARNING

The TripSaver II Cutout-Mounted Recloser MUST be de-energized and removed from the utility pole before  
attaching the “corded” power module (power module with ac adapter and extension cord) to the base of the 
TripSaver II recloser . The corded power module is ONLY intended to be used for set-up and data collection when the 
TripSaver II recloser is de-energized and removed from the utility pole . (To provide power to a TripSaver II recloser 
while it is mounted to the pole, use the cordless power module, S&C catalog number 5954 .) Failure to remove the 
TripSaver II recloser from the utility pole before connecting the corded power module may cause arcing, burns,  
electric shock, and death .

 

DANGER

The TripSaver II Cutout-Mounted Recloser operates at high voltage. Failure to 

observe these precautions will result in serious personal injury or death.
Some of these precautions may differ from your company’s operating procedures 
and rules . Where a discrepancy exists, follow your company’s operating procedures 
and rules .

1 . 

QUALIFIED PERSONS. Access to TripSaver II 

Cutout-Mounted Reclosers must be restricted only 
to qualified persons . See the “Qualified Persons” 
section on page 2 . 

2 . 

SAFETY PROCEDURES. Always follow safe 

operating procedures and rules .

3 . 

PERSONAL PROTECTIVE EQUIPMENT. Always 

use suitable protective equipment, such as rubber 
gloves, rubber mats, hard hats, safety glasses, and 
flash clothing, in accordance with safe operating 
procedures and rules .

4 . 

SAFETY LABELS AND TAGS. Do not remove or 

obscure any of the “DANGER,” “WARNING,” 
“CAUTION,” or “NOTICE” labels and tags . Remove 
tags ONLY if instructed to do so .

5 . 

ENERGIZED COMPONENTS. Always consider all 

parts live until de-energized, tested, and grounded .

6 . 

OPERATING TOOLS. To close a TripSaver II 

Cutout-Mounted Recloser, use a conventional 
insulated hotstick or S&C Universal Pole and Pole 
Extension fitted with a Talon™ Handling Tool or 
distribution prong . An extendostick also can be 
used after proper training and practice . The 
TripSaver II Cutout-Mounted Recloser can be 
opened using Loadbuster® —The S&C Loadbreak 
Tool attached to a conventional insulated hotstick 
or S&C Universal Pole .

7 . 

MAINTAINING PROPER CLEARANCE. Always 

maintain the proper clearance from energized 
components . 

Summary of Contents for TripSaver II

Page 1: ...per Application 2 Warranty 2 Safety Information Understanding Safety Alert Messages 3 Following Safety Instructions 3 Replacement Instructions and Labels 3 Safety Precautions 4 Hardware Contents of Co...

Page 2: ...used Retain this instruction sheet in a location where you can easily retrieve and refer to it Proper Application WARNING The TripSaver II Cutout Mounted Recloser must only be used for a specific prot...

Page 3: ...ns are not followed NOTICE NOTICE identifies important procedures or requirements that can result in product or property damage if instructions are not followed Following Safety Instructions If you do...

Page 4: ...electric shock and death DANGER The TripSaver II Cutout Mounted Recloser operates at high voltage Failure to observe these precautions will result in serious personal injury or death Some of these pre...

Page 5: ...er Module Extension cord for ac adapter USB transceiver Carrying case Blank adhesive labels transparent overlay also included for writing user configuration parameters To be attached to the left side...

Page 6: ...d the user a new username and password Users who already have a password can click on the Log in to the Secure Site button Enter a username and password to log in to the portal Download the SCCv1 9 In...

Page 7: ...eps to connect to a TripSaver II recloser to apply new settings STEP 1 Install the USB transceiver A USB transceiver firmware version 1 6 must be installed on the computer to communicate with a TripSa...

Page 8: ...tlet See Figure 5 e To verify the TripSaver II recloser is powered rotate the MODE SELECTOR lever and observe the LCD screen If the LCD screen begins to scroll it indicates the unit has been successfu...

Page 9: ...e 7 Download a free smart phone QR scanner app and scan the QR code to obtain the transceiver ID Some smart phones have QR code scanners built into their cameras b Method 2 Rotate the mode selector le...

Page 10: ...its of the ID are pre typed so only the last 16 digits must be typed in See Figure 10 c During the connection process a status bar will be displayed See Figure 11 Wait about 10 seconds for the connect...

Page 11: ...S C Instruction Sheet 461 503 11 Downloading Full Instruction Sheet 461 504 Download Instruction Sheet 461 504 at sandc com 461 504...

Reviews: