10 S&C Instruction Sheet 766-512
Installation
Figure 5. An external power supply connected to the IntelliRupter fault interrupter.
Page 1: ...s Instruction Sheet 2 Retain this Instruction Sheet 2 Proper Application 2 Special Warranty Provisions 2 Safety Information Understanding Safety Alert Messages 3 Following Safety Instructions 3 Replac...
Page 2: ...s publication must be selected for a specific application The application must be within the ratings furnished for the selected equipment Special Warranty Provisions The standard warranty contained in...
Page 3: ...ns are not followed NOTICE NOTICE identifies important procedures or requirements that can result in product or property damage if instructions are not followed Following Safety Instructions If you do...
Page 4: ...rrupter from steel brackets attached to the shipping skid 4 Slowly and carefully lift IntelliRupter fault interrupter onto pole or structure 5 Securely bolt IntelliRupter fault interrupter to pole or...
Page 5: ...e energized tested and grounded The integrated power module IPM contains components that can retain a voltage charge for many days after the IntelliRupter fault interrupter has been de energized and c...
Page 6: ...d must be grounded to the IntelliRupter fault interrupter base See Figure 1 and Figure 3 on page 9 Figure 1 The external power supply installed on a pedestal mounted IntelliRupter fault interrupter Tw...
Page 7: ...s steel medium pattern lockwasher 1323 056 9 2 5 16 flat 18 8 stainless steel washer 1340 016 Inspection Examine the shipment for external evidence of damage as soon after receipt as possible If there...
Page 8: ...the IntelliRupter fault interrupter base hardware reference numbers are indicated See Figure 2 3 4 6 5 Flexible ground strap IntelliRupter fault interrupter base External power supply Mounting bracket...
Page 9: ...S C Instruction Sheet 766 512 9 Installation Figure 3 Grounding the external power supply to the IntelliRupter fault interrupter base Figure 4 Ground nut and washers reference numbers indicated 7 8 9...
Page 10: ...10 S C Instruction Sheet 766 512 Installation Figure 5 An external power supply connected to the IntelliRupter fault interrupter...
Page 11: ...e Figure 7 on page 11 STEP 3 Use ring terminals to connect control power to thetopterminals Wiremustbesizedsufficiently toprovide6amperesforallinputvoltageranges See Figure 8 on page 11 Figure 6 Junct...
Page 12: ...12 S C Instruction Sheet 766 512 Installation Figure 7 Junction box mounted on the IntelliRupter fault interrupter pedestal Figure 8 Junction box power input terminals Knockouts...