S&C IntelliRupter PulseCloser P300 Installation Manual Download Page 1

November 18, 2019
©  S&C Electric Company 2012-2019, all rights reserved

Instruction Sheet  766-512

IntelliRupter

®

 PulseCloser

®

 Fault Interrupter

Outdoor Distribution (15.5 kV, 27 kV, and 38 kV)

Section  

Page

Section  

Page

Introduction

Qualified Persons     .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Read this Instruction Sheet    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Retain this Instruction Sheet    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Proper Application    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Special Warranty Provisions    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2

Safety Information

Understanding Safety-Alert Messages    .  .  .  .  .  .  .  .  .  . 3
Following Safety Instructions   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Replacement Instructions and Labels    .  .  .  .  .  .  .  .  .  .  . 3
Location of Safety Labels     .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4

Safety Precautions

   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5

Overview

   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

Inspection

Inspection     .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7
Parts List    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7

Installation

Install External Power Supply    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8
Install Junction Box    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .11

Table of Contents

External Power Supply Installation

Summary of Contents for IntelliRupter PulseCloser P300

Page 1: ...s Instruction Sheet 2 Retain this Instruction Sheet 2 Proper Application 2 Special Warranty Provisions 2 Safety Information Understanding Safety Alert Messages 3 Following Safety Instructions 3 Replac...

Page 2: ...s publication must be selected for a specific application The application must be within the ratings furnished for the selected equipment Special Warranty Provisions The standard warranty contained in...

Page 3: ...ns are not followed NOTICE NOTICE identifies important procedures or requirements that can result in product or property damage if instructions are not followed Following Safety Instructions If you do...

Page 4: ...rrupter from steel brackets attached to the shipping skid 4 Slowly and carefully lift IntelliRupter fault interrupter onto pole or structure 5 Securely bolt IntelliRupter fault interrupter to pole or...

Page 5: ...e energized tested and grounded The integrated power module IPM contains components that can retain a voltage charge for many days after the IntelliRupter fault interrupter has been de energized and c...

Page 6: ...d must be grounded to the IntelliRupter fault interrupter base See Figure 1 and Figure 3 on page 9 Figure 1 The external power supply installed on a pedestal mounted IntelliRupter fault interrupter Tw...

Page 7: ...s steel medium pattern lockwasher 1323 056 9 2 5 16 flat 18 8 stainless steel washer 1340 016 Inspection Examine the shipment for external evidence of damage as soon after receipt as possible If there...

Page 8: ...the IntelliRupter fault interrupter base hardware reference numbers are indicated See Figure 2 3 4 6 5 Flexible ground strap IntelliRupter fault interrupter base External power supply Mounting bracket...

Page 9: ...S C Instruction Sheet 766 512 9 Installation Figure 3 Grounding the external power supply to the IntelliRupter fault interrupter base Figure 4 Ground nut and washers reference numbers indicated 7 8 9...

Page 10: ...10 S C Instruction Sheet 766 512 Installation Figure 5 An external power supply connected to the IntelliRupter fault interrupter...

Page 11: ...e Figure 7 on page 11 STEP 3 Use ring terminals to connect control power to thetopterminals Wiremustbesizedsufficiently toprovide6amperesforallinputvoltageranges See Figure 8 on page 11 Figure 6 Junct...

Page 12: ...12 S C Instruction Sheet 766 512 Installation Figure 7 Junction box mounted on the IntelliRupter fault interrupter pedestal Figure 8 Junction box power input terminals Knockouts...

Reviews: