CWFL-3000 Series
18
<9> Simple troubleshooting
Failure
Failure Cause
Approach
Machine turned on but unelectrified
Power cord is not plugged in place
Check and ensure the power interface
and the power plug is plugged in place
and in good contact
Fuse burnt-out
Open the electric box cover, check the
protective tube, replace with spare one
if necessary and check whether the
power supply voltage is stable; Check
and ensure the power interface and
the power plug are in good contact
Flow Alarm
(controller displays E01 or E02) use a
water pipe directly connect to the
water outlet and inlet but still without
water flowing
Water level in the storage water tank is
too low
Check the water level gauge display,
add water until the level shown in the
green area; And check whether water
circulation pipe leaks
Flow alarm occurs while running with
other equipment (controller displays
E01 or E02), but there is water flowing
and no alarm when use a water pipe
directly connected to the chiller water
outlet and inlet.
Water circulation pipes are blocked or
a pipe bending deformation.
Check water circulation pipe
Ultra-high temperature
alarm(controller displays E05 or E07)
Blocked dust gauze, bad thermolysis
Unpick and wash the dust gauze
regularly
Poor ventilation for air outlet and inlet
To ensure a smooth ventilation
for air outlet and inlet
Voltage is extremely low or astable
To improve the power supply circuit or
use a voltage regulator
Improper parameter settings on
thermostat
To reset controlling parameters or
restore factory settings
Switch the power frequently
To ensure there is sufficient time
for refrigeration
(more than 5 minutes)
Excessive heat load
Reduce the heat load or use other
model with larger cooling capacity
Alarm for ultra-high room
temperature(controller displays E03)
The working ambient
temperature is too high for the chiller
To improve the ventilation to guarantee
that the machine is running under
40
℃
.
Serious problem of condensate water
Water temperature is much lower than
ambient temperature, high humidity
Increase water temperature or
to preserve heat for pipeline
Water drains slowly from outfall during
water changing
Injection port is not open
Open the injection port
Summary of Contents for CWFL-3000BT
Page 1: ...CWFL 3000 DUAL TEMPERATURE AND DUAL PUMP INDUSTRIAL CHILLER USER MANUAL...
Page 19: ...CWFL 3000 Series 19 CWFL 3000...
Page 20: ...CWFL 3000 Series 20 21 22 23 24 29 29 MODBUS RS 485 30 33 34...
Page 21: ...CWFL 3000 Series 21 1 2 10 3 50Hz 60Hz 4 NORMAL NORMAL 5 50cm 30cm 6 7 8...
Page 22: ...CWFL 3000 Series 22...
Page 23: ...CWFL 3000 Series 23 1 2 3 4 1 2 3 4 5 6 CWFL 3000 25 24...
Page 28: ...CWFL 3000 Series 28 E16 E16 E17 E17 E18 E18 E19 E19 E20 E20 E21 E21...
Page 34: ...CWFL 3000 Series 34 E01 E02 E01 E02 E05 E07 E03 40...