- 5 -
- 4 -
1 , 2
I N S T A L L F A U C E T
TEMPERATURE CONTROL
10
20
21
32
33
22
23
1. Installation
(1) Connect water supply line with faucet body(10). (Tighten the union nut.)
The SAN-EI logo on the faucet body(10) should face the inside of the bath tub.
(If you install the opposite direction, faucet spout(25) can not be installed.)
(2) The cure cap should be covered until the tiles are laid. The cure cap
indicates the level where the surface should be finished.
NOTE
: Please pay attention to the level indication whether finished surface is
within the mentioned level or not.
NOTE
: Please pay attention the installation, not to put sand or mortar into the
faucet body(10) or cure caps.
2. Inspection
After installing and connecting the faucet body(10), turn on supply valve to check
the water leakage.
3. Assemble parts
All thread portions and spindle portions should be covered or wrapped with a
material such as vinyl in advance.
4. Tile finishing
Please pay attention that the finished surface of tiling should be within the
mentioned level or not.
5. Remove "cure caps" from the faucet body
Water temperature is adjustable by rotating the temperature handle.
Cure Cap
SAN-EI Logo
Cure Cap
Standard
Level
Upper
Level
Bottom
Level
Safety Lock Button
Safety Lock Button
4 , 5
3
Vinyl Cover
Put a grain of sand
to be fixed
8
Cure Cap
Tile Surface
H O W T O A D J U S T T H E T E M P E R A T U R E
Stop
Flow
By adjusting the temperature control
volume, you can get a comfortable
water temperature.
The temperature indication mark should
be used as a criterion temperature.
If you want to get a water temperature
over 40 C, please rotate the handle
while pushing the safety lock button.