T E M P E R A T U R E   C A L I B R A T I O N

O P E R A T I O N

Tile Surface

4-9/10"(125mm)

Socket

Union 

Nut

3-3/5"(92mm)
1/5"(5mm)

5-1/5"(133mm)    

1/5"(5mm)

5-9/10"(150mm)

3-9/10"(100mm)

7-1/10"(180mm)

5-9/10"(150mm)

3-3/10"(85mm)

4-3/10"(110mm)

4-9/10"(125mm)

9-2/5"(240mm)

Please connect socket with union nut onto 
supply pipe. 
Then, the length between the top surface 
level and the supply the level should keep 
3-3/5"(92mm)      1/5"(5mm). 
(Both supply line levels should be the 
same level as each other.)

Installation Dimension

Rim Width

Below 3-3/10"(85mm)

3-9/10"(100mm)

4-7/10"(120mm)

5-1/2"(140mm)

Over 5-1/2"(140mm)

Between 2-3/5"(65mm) to 4-7/10"(120mm)

Between 2-3/5"(65mm) to 4-1/10"(105mm)

Between 2-3/5"(65mm) to 3-3/10"(85mm)

Between 2-3/5"(65mm)

Can not be used.

3-1/2"(90mm)

Between 2-3/5"(65mm) to 4-1/2"(115mm)

A

Spout 9-2/5"(240mm)

2-1/5"(56mm)    

1/5"(5mm)

4-1/5"(106mm)

Spout 9-2/5"
(240mm)

Rim Width

A

MIN 3-1/10"
(80mm)

MIN 5-9/10"
(150mm)

Over 8-7/10"(220mm)

4-9/10"(125mm)

 3-1/10"

(80mm)

Over 1-2/5"(35mm)

Supply pipe for 
cold water

Supply pipe for 
hot water

1/2-14 NPT

6. Assemble handles and faucet spout

To protect water going to the cracked space 
of tiles, put the sealing material to the 
cracked space. Then, assemble handles(12) 
and spout(25), referring to the following 
indication. (Excess sealing should be 
removed perfectly.)

6

2

12

11

25

24

7

8

9

13
14

Sealing

1

2

3

1

2

3

Safety Lock 
Button

40 Mark

40

Please follow the installation dimensions carefully. 
Improper installation may result in the prevention 
of water flowing directly into the tub.

4 Limit Stop Ring

1.

 Remove the handle cap and screw. Please adjust the handle to 40 C.

2.

 After making sure that the temperature is 40 C, remove the handle.

3.

 The safety lock button should be put to the 40 C mark on the temperature 

    indication plate.

NOTE

 

:

Temperature indication on the temperature indication plate should be used as a 
criterion point. (Even though temperature is adjusted by using the temperature 
indication plate, the temperature mark does not guarantee the actual water 
temperature.)  

NOTE

 

:

When attaching the temperature handle to the faucet body, don’t rotate the spindle.

CAUTION!

49 degreesC (120 degreesF) is an industry standard for 
maximum discharge water temperature from tub and 
shower valve. This maximum temperature may vary in 
your local area.
To set this maximum discharge temperature, adjust the 
position of the limit stop ring.
Moving the limit stop ring counterclockwise will reduce the 
maximum discharge temperature.

Summary of Contents for K987D-L-BW

Page 1: ...te of purchase 2 SAN EI warrants to the Commercial Purchaser that their products purchased for commercial industrial or other business use are free from defects of workmanship and materials for a period of 1 year after the date of purchase All warranties are to the original purchaser and require presentation of original sales receipt Warranty is not transferable During the warranty period SAN EI w...

Page 2: ...luids will discolor or remove chrome plating Care and Cleaning of Chrome and Special Finishes FLUSHING INSTRUCTIONS TROUBLESHOOTING IMPORTANT Pipe chips sand stones and other solid found in new and renovated plumbing can damage the cealing of the cartridge and cause leaks To avoid damage DO NOT TURN ON SUPPLY VALVES until instructed below 1 After installing and connecting your new faucet turn on i...

Page 3: ...ealing material to the cracked space Then assemble handles 12 and spout 25 referring to the following indication Excess sealing should be removed perfectly 6 2 12 11 25 24 7 8 9 13 14 Sealing 1 2 3 1 2 3 Safety Lock Button 40 Mark 40 Please follow the installation dimensions carefully Improper installation may result in the prevention of water flowing directly into the tub 4 Limit Stop Ring 1 Remo...

Page 4: ... body 10 turn on supply valve to check the water leakage 3 Assemble parts All thread portions and spindle portions should be covered or wrapped with a material such as vinyl in advance 4 Tile finishing Please pay attention that the finished surface of tiling should be within the mentioned level or not 5 Remove cure caps from the faucet body Water temperature is adjustable by rotating the temperatu...

Page 5: ... body 10 turn on supply valve to check the water leakage 3 Assemble parts All thread portions and spindle portions should be covered or wrapped with a material such as vinyl in advance 4 Tile finishing Please pay attention that the finished surface of tiling should be within the mentioned level or not 5 Remove cure caps from the faucet body Water temperature is adjustable by rotating the temperatu...

Page 6: ...ealing material to the cracked space Then assemble handles 12 and spout 25 referring to the following indication Excess sealing should be removed perfectly 6 2 12 11 25 24 7 8 9 13 14 Sealing 1 2 3 1 2 3 Safety Lock Button 40 Mark 40 Please follow the installation dimensions carefully Improper installation may result in the prevention of water flowing directly into the tub 4 Limit Stop Ring 1 Remo...

Page 7: ...luids will discolor or remove chrome plating Care and Cleaning of Chrome and Special Finishes FLUSHING INSTRUCTIONS TROUBLESHOOTING IMPORTANT Pipe chips sand stones and other solid found in new and renovated plumbing can damage the cealing of the cartridge and cause leaks To avoid damage DO NOT TURN ON SUPPLY VALVES until instructed below 1 After installing and connecting your new faucet turn on i...

Reviews: