background image

 

 

7

 

Chapter 1. Overview 

  GMDSS(Global  Maritime  Distress  and  Safety 

System)  is  an  internationally  recognized  distress 
and  radio  communication  safety  system  for  ships 
replacing  the  previous  ship  to  ship  safety  system, 
which  relied  on  a  manual  Morse  code  system  on 
500  kHz  and  voice  radiotelephony  on  Channel  16 
and 2182 kHz. The GMDSS is an automated ship to 
shore  system  using  satellites  and  digital  selective 
calling technology. 
The GMDSS is mandated for ships internationally by 
the  International  Maritime  Organization  (IMO) 
Safety of Life at Sea Convention (SOLAS), 1974, as 
amended  in  1988,  and  carries  the  force  of  an 
international treaty. 

  SRG-3150  and  SN-100  are  composed  of  MF/HF 

transceiver,  DSC,  DSC  W/K  Receiver,  NBDP, 
Automatic  alarm  telephone  for  suitable  automatic 
digital 

communication 

at 

the 

distress 

and 

safety/normal situation. 
SN-100  uses  being  connected  to  Transceiver(SRG-
3150DN),  output  sub-carrier  signal  to  transmit 
NBDP data, displays the information on the display 
which  is  demodulated  RX  signal  receiving  from 
antennas. 
 

 SRG-3150DN frequency range :   

TX : 1.6MHz~27.5MHz 
RX : 500kHz~29.99999MHz 

 

 Type of Frequency/Power :   

J3E : 150W(HIGH)/100W(MID)/50W(LOW),   
F1B : 100W(HIGH&MID)/75W(LOW). 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1.1. Features 

(1) Possible Range   

  Because  MF/HF  Transceiver(SRG-3150DN),  DSC 

W/K Receiver, DSC, Distress alarm telephone is built 
in  SRG-3150DN,  You  are  able  to  use  itself  without 
NBDP  terminal(SN-100).  NBDP  function  is  worked 
by  connecting  SN-100  terminal,  However  it  is  not 
available to use NBDP terminal only. 
 
(2) Total Control System 

  SRG-3150DN  is  set  up  with  the  major  modules 

combined  as  one  unit  or  circuits  within  a  single 
cabinet.  Thus,  it  is  possible  to  rationalize  the  total 
control system by interlinking the respective module 
controls. 

  And  narrow  band  direct  printing  is  available  by 

connecting  NBDP  unit(SN-100)  to  SRG-3150DN 
simply. 
 
(3) User Friendly 

  All  general  operation  such  as  communication, 

controls  and  monitoring,  are  performed  by  SRG-
3150DN,  NBDP  Terminal  and  printer  which  is 
installed in a convenient place. 
 
(4) Configuration 

  SRG-3150DN  consists  of  one  unit;  therefore  a 

large  space  is  not  required  for  installation  and 
operation.   

 SN-100 Terminal is able to use by connecting with 

SRG-3150DN cable. 
 
(5) Trustworthy 
Adopted  new  DDS  (Direct  Digital  Synthesize)  and 
improved the quality of sound, trustworthy, stability. 
 
(6) Construction 

  In  order  to  endure  in  bad  condition  of  marine 

environment, hard aluminum body is manufactured. 
 
(7) External Shape 

  Channel,  Frequency,  Transmitting  and  receiving 

conditions  can  be  seen  on  large  LCD  at  one  sight. 
And  each  key  is  made  by  soft  rubber  material.  It 
has  stylish  shape  and  makes  you  feel  comfortable 
when  you  press  the  button,  Further  there  is 
frequency  sheet  for  users.  SN-100  NBDP  Terminal 
has  large,  thin,  colorful  LCD  and  convenient 
keyboard. 

 

Summary of Contents for SRG-315DN

Page 1: ...al operation Information to user The user s manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the...

Page 2: ...atures 7 1 2 Basic Components 8 Chapter 2 Specifications 9 2 1 General specification 9 2 2 MF HF Transmitter 9 2 3 MF HF Receiver 9 2 4 DSC Digital Selective Calling W K Receiver 10 2 5 MF HF Control...

Page 3: ...32 Chapter 8 RX of Distress general call 33 8 1 RX of Distress Alarm 33 8 2 General call RX 34 Chapter 9 How to use print 35 9 1 DPU 414 Printer 35 9 2 OKI Printer 35 Chapter 10 How to use SD 250 Ala...

Page 4: ...mmunication in FEC mode 47 4 Receiving of FEC mode 47 5 Transmitting file 48 6 Transmitting of Macro Command 48 13 6 Other sea station or ship station edit resister frequency 48 13 7 Station print Cou...

Page 5: ...Power Supply 54 3 Transmitter 54 4 Receiver 54 5 DSC Receiver 54 6 Switch and Display 55 15 4 NBDP SN 100 55 1 Power Supply 55 2 Screen Display 55 3 NBDP Data Receiving 55 4 NBDP Data Transmitting 55...

Page 6: ...utton press 2 Press twice and select to RX Input frequency by No button press Ref Missing frequency range Cannot be input with alarm sound 2 3 TX RX 1 TX Can use it after inputting to the frequency TX...

Page 7: ...ransmit signal 2 If you don t have any reply flicker the red DISTS display as follow on screen and transmit channel from 1 to 6 after 4 minutes 3min and 30sec 4min 40sec 3 Press and then stop to trans...

Page 8: ...alarm telephone is built in SRG 3150DN You are able to use itself without NBDP terminal SN 100 NBDP function is worked by connecting SN 100 terminal However it is not available to use NBDP terminal on...

Page 9: ...30 1 2 NBDP T 132 1 3 NBDP PLL T 133 1 4 T 025 1 5 CPU Board G 1151 1 5 KEY Board SPR8695 1 6 MF HF Distress Box SD 250 1 SCN 16 5P included 7 Printer DPU 414 1 Installation material included or OKI P...

Page 10: ...Frequency Deflection Below 10Hz within 0 3ppm 7 Number of Channels SSB x 299 ITU x 271 DSC x 19 8 Modulation type Low power stage balanced modulation 9 Occupied Bandwidth J3E within 3kHz J2B within 0...

Page 11: ...or each frequency and stop only when detects a 100 baud dot pattern 5 Receiving Sensitivity Character error rate is 1 x 10 2 or less at receiving input voltage 1 6 1 signal selectivity 6dB bandwidth 2...

Page 12: ...y 40letters Standard 80letters Shortened Typing Direction Single Both Logical seek 2 Bit image graphics mode Total Dots 8 x 320 dot line Typing Direction Single Logical seek Typing width 89 6mm Typing...

Page 13: ...MF HF control panel will light up automatically When it is transmitted to DSC AC signal will be changed to DC on upside of transceiver LCD display Moreover changing to DC mode will be displayed on do...

Page 14: ...essages ON OFF in DSC mode 5 Selecting main menu 6 Hold this key and extend functions with random keys Selecting CH TX RX in Order Be available to select Channel and TX RX Frequency Select ATT in orde...

Page 15: ...10 10 10 10 Switch SSB DSC mode Holing FUNC and press MODE Switch AM mode Ref SSB J3E use to voice communication DSC F1B use to digital selective calling communication 11 Matching with user s antenna...

Page 16: ...standing wave ratio VOLT PS current IC TX current ANT Antenna currency indicate to date and time and automatic indicate to UTC when connected GPS GPS receiver q Indicate GPS received date latitude lo...

Page 17: ...annel Speed Set speed of scan channel 0 9 0 Fastest 9 Slowest 3 Scan Frequency Set a Set value in case of scanning Frequency 3 Scan Freq Set is selected The below box shows Start End Speed Step 500 00...

Page 18: ...8 ATU Version is selected Selected Ref if ATU DATA cable has any trouble Display Error 9 Remote Set a Set remote operating 9 Remote OFF is selected Press can be changed 9 Remote ON Display REM on the...

Page 19: ...Key Test Test button the front screen 9 Key Test is selected When press selected button and then display title that selected button on the screen 5 3 Additional Functions ITU Channel AM mode Etc 1 ITU...

Page 20: ...nnels Select Channel that format is Distress Press display can edit msg on the screen Or can be edited what you want FORMAT A kind of calling Distress Distress calling fixed NATURE The type of distres...

Page 21: ...ing up and down with 1 step channel Moving up and down with 10 step channels The channel is selected The below box shows TX Freq Set TX frequency Move to TX Freq The below box shows 01 02 03 04 05 06...

Page 22: ...d register select WORK FRQ press to change WORK FRQ POSITION Select POSITION by Input by No button c After setting items press and individual call signal transmits d When ACK response signal is receiv...

Page 23: ...ice MENU 9 SYSTEM SET 5 ID FR TEL Set 3 Work Frequency Edit and register c After setting items press and group call signal transmits d When ACK response signal is received communication can be possibl...

Page 24: ...Selected WORK FRQ Operational frequency Move to WORK FRQ Selected Number button input TX frequency Set up Number button input RX frequency Set up EOS Completion of DSC message EOS Auto set fixed c Fun...

Page 25: ...00 90 E _ _ East longitude 000 180 W _ _ _ West longitude 000 180 DA _ _ Latitude range Offset Value Do _ _ Longitude range Offset Value Number button Input the value Set up Ref every press N_ _ E_ _...

Page 26: ...g fixed CATEGORY Purpose of calling Routine use generally fixed PARTY ID Input ID Move to PARTY_ID Press Number button Input ID Set up TEL CMD1 Set Telecommand1 Move to TEL CMD1 The below box shows Go...

Page 27: ...to respond to distress signal and manual relay of the distress message 6 Dist ack rly msg edit is selected The below box shows b It is memory channel using from 400 to 499 as right on the top Ref Movi...

Page 28: ...ted POSITION Input the Position of the vessel in distress Move to POSITION The below box shows N _ _ _ _ _ _ _ _ E _ _ _ _ _ _ _ _ _ North latitude 00 00 0000 90 00 0000 east longitude 000 00 0000 180...

Page 29: ...hannel c If this mode is selected with the printer connected printing of the message starts automatically 9 System Set a in case of setting the value of SYSTEM 9 System Set is selected The below box s...

Page 30: ...elect Character move The below box shows 0 0 0 0 0 0 0 0 0 Number button Input ID Set up If want to return menu Ex How to input ID and ship s name SAMYUNG 101010000 It is input as below Ref Blank is f...

Page 31: ...selected The below box shows 1 Dot Transmit 2 Mark transmit 3 Space Transmit Send Dot signal only Send Mark signal only Send space signal only Ref select on of them by press and then it is transmitte...

Page 32: ...Range is selected Press to change 120 240 360 500 600 NM Ref MENU 4 Geography msg edit on screen In case of setting PARTY AD area range just input latitude and longitude and press and then setting val...

Page 33: ...01 02 03 04 05 06 2 187 5 4 207 5 6 312 0 8 414 5 12 577 0 16 804 5 2 If don t have a answer flicker DISTS LED and shown following screen and then after 4 minutes 3min 30sec 4min 40sec transmit chann...

Page 34: ...RX Press button to stop the alarm Press button and stop the alarm Rx ACK within 3 min from CRS Alarm sounds Check the saved messages Beyond 150 nm from own ship Is the distressed vessel near own ship...

Page 35: ...is on ACK reply is transmitted Automatically the frequency is shifted to voice communication frequency and then voice communication is possible RX Individual Call In case Auto ACK set is off press but...

Page 36: ...PER COVER Store up the paper inside it 3 Usual operation Check the main unit of SRG 3150DN is turned on If power on it is able to print TX RX DSC MESSAGE and DATA from SRG 3150DN automatically 4 How t...

Page 37: ...In case of AC Power stopping the buzzer is ringing and LED green light of AC OFF is on In order to stop the buzzer s ringing you can turn to OFF in the switch of ALARM 11 3 How to Charge 1 In case of...

Page 38: ...er circuit Control circuit MF HF Transmitting filter circuit Front Interface W K Receiving Circuit At the rear side of this equipment there are connectors connected with ATU BOX SAT 100 SP 1250 ALARM...

Page 39: ...3 and IF amplifier Q21 Q23 Q950 and In 3 rd MIXER IC15 it is demodulated to a signal of baseband with BFO Beat Frequency OSC The demodulated signal is divided to 3 species as follows Amplifiable signa...

Page 40: ...oltage to be constant voltage in each unit AUDIO AMP for external speaker and operate through DC INPUT 24V BATTERY Main Power Circuit and Power Control Circuit When switch on it controls Relay goes th...

Page 41: ...pass signal LOCAL CONTROL to indicate various information receiving frequency receiving mode band width set by operating panel of controller unit and transmit in control unit Except this function in c...

Page 42: ...iate frequency 1 st IF 49 455MHz and it goes through X tal filter IF amplifier then is supplied to 2 nd MIXER and in 2 nd MIXER is mixed with 2 nd local frequency W K 2 nd LO 49MHz and converted to 2...

Page 43: ...onnector Control Cable AC DC Power Supply SP 1250 connector AC DC Detect ALARM BOX ALARM BOX SD 250 connector PRT or D L 9 PRINTER OKI DPU 414 connector or PROGRAM Down Load connector REMOTE 9 REMOTE...

Page 44: ...g up down button OFF 0dBm 2 20 dBm 1 10dBm 3 30 dBm Adjust TX power HIGH MID LOW Profit of input signal ON OFF automatically Volume sound is displayed on Graphic bar 0 100 levels 2 Initial screen func...

Page 45: ...button b Input the frequency with Number button Ref While inputting frequency if press curser will move c Press Enter button Ref Available RX Frequency range 95 KHz 29 99999MHz 3 Coast Radio Station...

Page 46: ...an keep communicating in this condition b After typing the message with keyboard press Enter button Ref Back space delete one character on the left Before you press Enter button transmitting is not co...

Page 47: ...reen Ref pressing F8 button is able to stop transmitting 13 5 FEC mode 1 Connecting the other station by Selective FEC mode Communication with present selecting Channel a Press F2 button on the keyboa...

Page 48: ...jklmnopqrstuvwxyz Back space Delete one character on the left Enter Send one line Left Shift Space Convert language English Russian Korean is selected Korean English shift English is selected English...

Page 49: ...ship station edit resister frequency a Press F10 button on the keyboard and Main Menu screen shows b Move the cursor to 2 Station Edit with button Press Enter and the following screen shows c Revert t...

Page 50: ...stration of macro command Can resister TXL number that is often used or abbreviated words in 20 words a Press F10 button on the keyboard and Main Menu screen shows b Move the cursor to 4 Macro Command...

Page 51: ...d and back to Main Menu Ref this will be done during installation and the user can not change 2 Setting of 1 ARQ FEC 9 digit ID After b select 1 ARQ FEC 9 digit ID Enter input the ID with Number butto...

Page 52: ...X starting message X Not Recognized as NAVTEX starting message Ref A B D is set up as RX always 8 Selecting of 7 NAVTEX ID Data Clear Use this menu to delete the received Navtex ID How to set up After...

Page 53: ...ves the signal and compensate the 1st local frequency 6 Freq Shift View After Freq Shift Correct this shows how well the frequency compensation is done Ref press Enter button or ESC button and it will...

Page 54: ...uld be mixed And then MARK 1 7kHz 85Hz and SPACE 1 7 kHz 80 Hz signals are generated One side is delivered to SRG 3150DN through attenuator and matching tool 14 4 Local Synthesizer board T 133 As T 13...

Page 55: ...eiver d After connecting the high frequency wattmeter between this equipment and ATU measure the progress wave and the reflected wave If the VSWR Voltage Standing Wave Ratio is less than 2 1 the conne...

Page 56: ...d Firstly check that ANT is correctly connected Check that 12V is generated on U1 of T 025 Check that SRG 3150DN receive W K signal If SRG 3150DN does not receive W K signal Check the third pin IC4 of...

Page 57: ...56 Chapter 16 Circuit Diagram External Diagram...

Reviews: