Installation
English
24
Installation
4-wire system
F
A B
C L2
L1
D
E
A.
External ground connector
B.
Neutral grounding wire (white)
C.
Center silver-colored terminal block
screw
D.
Neutral wire (white or center wire)
E.
¾” (1.9 cm) UL-listed strain relief
F.
Neutral wire (white or center wire)
1.
Remove the external ground
connector’s screw and connect the
ground wire (green or unwrapped) of
the power cable to the screw.
CAUTION
- To connect the ground wire to the
neutral position without through
contact A (cabinet ground), contact
a technician. This is not user
serviceable.
- Ring-type terminals are
recommended. If using strap
terminals, make sure they are
tightened.
2.
Loosen or remove the screws from the
center terminal block.
3.
Connect the neutral wire (white or
center wire) and ground wire (white) to
the center screw of the terminal block.
Tighten the screw.
4.
Connect the other wires to the outer
terminal block screws. Tighten the
screws.
5.
Tighten the strain relief screws.
6.
Insert the tab of the terminal block
cover into the rear slot of the dryer.
Secure the cover with a hold-down
screw.
CAUTION
Before Installing the Dryer, confirm 240 V is present between L1 and L2 at the power
receptacle. If the Voltage is low, it may not dry properly. Review the “
” section on page
Untitled-18 24
2020-07-14 3:40:07
Summary of Contents for DVG54R7200 Series
Page 1: ...Dryer User manual DVE G 54R7600 DVE G 54R7200 Untitled 18 1 2020 07 14 3 40 03...
Page 61: ...Memo Untitled 18 61 2020 07 14 3 40 17...
Page 62: ...Memo Untitled 18 62 2020 07 14 3 40 17...
Page 63: ...Memo Untitled 18 63 2020 07 14 3 40 17...
Page 65: ...Secadora Manual del usuario DVE G 54R7600 DVE G 54R7200 Untitled 19 1 2020 07 14 3 42 06...