71
Step 2
Set the values for Detect Period and Read times of light sensors. Detect Period is the time
period the light sensors measure the environment brightness. Read times of light sensors is
the times that NovaLCT-Mars reads the measurement results of the light sensors. Thus the
auto brightness time interval is the production of Detect Period and Read times of light
sensors. For example, if light sensors measure the environment brightness every 10 second
(this is the Detect Period.) and NovaLCT-Mars reads the measurement results of the light
sensors for 5 times (this is the Read times of light sensor.) before adjusting the LED display
brightness, the auto brightness time interval will be 50 seconds.
Summary of Contents for XA060J
Page 1: ...1 Outdoor P6 Product User Manual Model Name XA060J Model Code LH060XAJSAC XX ...
Page 3: ...3 10 1 Cleaning 103 10 2 Calibration 104 10 3 Replacement steps 105 11 Appendix 117 ...
Page 12: ...12 3 2 Product Appearance ...
Page 13: ...13 ...
Page 14: ...14 3 3 Product design Decomposition chart ...
Page 15: ...15 Assembly drawing ...
Page 16: ...16 3 4 Product main components Module Power Supply Receiving Card Monitoring Card ...
Page 17: ...17 Fan Hub board Power data cables 16pcs DC power cables 8PCS and Flat cables 16 pcs ...
Page 35: ...35 Installation of cabinets Fixing of connect plate ...
Page 41: ...41 8 2 Port of Cabinet and serial number paint ...
Page 58: ...58 ...
Page 67: ...67 ...